Dimm Replacement Procedure - Cisco UCS C220 Installation And Service Manual

Hide thumbs Also See for UCS C220:
Table of Contents

Advertisement

Chapter 3
Maintaining the Server
Memory Mirroring
When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two
channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable
memory error, the system automatically retrieves the data from the other channel. A transient or soft error
in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous
error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the
amount of memory available to the operating system by 50% because only one of the two populated
channels provides data.
You must choose to enable memory mirroring in the server BIOS setup utility, under 
Note
Advanced > Memory Configuration > Mirroring.
If you choose to enable memory mirroring, populate the DIMM slots in the order shown in
Table 3-5
Number of DIMMs 
per CPU
4
6
8

DIMM Replacement Procedure

This section includes the following topics:
Identifying a Faulty DIMM
Each DIMM slot has a corresponding DIMM fault LED. See
The LEDs light amber to indicate a faulty DIMM. Power must be present in the server for these LEDs to
operate.
Replacing DIMMs
To install a DIMM assembly, follow these steps:
Step 1
Remove the DIMM that you are replacing:
a.
b.
If you cannot safely view and access the component, remove the server from the rack.
Caution
OL-25760-01
Memory Mirroring DIMM Population
CPU 1 Population
A1, B1; A2, B2
A1, B1; C1, D1; A2; B2
A1, B1; C1, D1; A2, B2; C2, D2 E1, F1; G1, H1; E2, F2; G2, H2
Identifying a Faulty DIMM, page 3-21
Replacing DIMMs, page 3-21
Power off the server as described in the
page
3-7.
Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Installing or Replacing Server Components
CPU2 Population
E1, F1; E2, F2
E1, F1; G1, H1; E2, F2
Figure 3-3
"Shutting Down and Powering Off the Server" section on
Cisco UCS C220 Server Installation and Service Guide
Table
3-5.
for the locations of these LEDs.
3-21