About the controlson the air conditionermmodels with touchpads.
Auxiliary Controls- TemperatureLimiting
To reach
the auxiliary
controls
remove
the fl'ont
g_ille. Access them through
the small rectangular
opening
above the control
panel.
Temperature
limiting
can reduce
energy
costs by limiting
the lowest temperature
that
can be set for cooling.
Temperature
limiting
is
controlled
bv switches
1-3 of a u_lia_w controls.
TL1(C){Temp. Limit1 Cod)
TL2(C){Temp. Limit2 Cool)
TL3(C}{Temp. Limit3 Cool}
UP
--
Nofunction(reserved
for futureuse)
DOWN
Temperature limiting during COOLmode
(all temperatures shown in °F)
UP
DOWN
Minimum
Maximum
NONE
1, 2, 3
60°
85°
1
2,3
64°
85°
1, 2
3
66°
85°
2
1,3
68°
85°
2,3
1
70°
85°
1, 2, 3
NONE
72°
85°
1,3
2
74°
85°
3
1, 2
76°
85°