INSTALLING THROUGH THE WALL
Read these
instructions
completely
and carefully.
[] PREPARE OPENING
IN WALL
Make certain a wall receptacle
is
available
close to the hole location
or make
arrangements
to install a receptacle.
The cord length for the 115-volt
models is 72"
to the right and 47" to the left.
For the 230/208-volt
models the cord length
is
65" to the right and 39" to the left.
[] SUPPORT REQUIREMENTS
FOR
AIR CONDITIONER
The air conditioner
wall case may be installed
with 1/4" min. extension
out from the inside
wall or with 1/4" min. extension
out from the
outside
wall.
The finished
sides of the opening
should
be
structural
wall members.
Lintel - Use a lintel in brick veneer and brick
and block types of wall to support the bricks
or blocks
above the opening.
Do not allow the
wall case to be used in lieu of a lintel.
Flashing-
Install flashing
(drip rail) as shown
to prevent water from dripping
inside the wall
and down
the outside
of the building.
Lintel
angle
(if required)
_
Plaster
Caulking
_
line
(on all 4_
sides on the
Trim
outside
of
molding
the case)
(if desired)
Room
side
Flashing
(drip rail)
i
1/4" min.
extension
J
inside the wall from
the trim
molding
[] SUPPORT REQUIREMENTS
FOR
AIR CONDITIONER
Mortar
between
the case and the brick all
around the case may be undercut
at about 45 °
for improved
caulking.
Inside
Top of case
Caulking
Outside
mortar
15