Furuno FR-2115-B Installation Manual page 28

Furuno marine radar user manual
Hide thumbs Also See for FR-2115-B:
Table of Contents

Advertisement

2.3.2 Connection of monitor cable inside the monitor
Connect the monitor cable inside the monitor as below.
MONITOR
REAR
VIEW
1
2
Connect to
CONNECTOR Board.
NH5P to J575
NH6P to J577
NH3P to J579
VH3P to J576
3
MONITOR CABLE
4
5
Clamp Plate
Earth Terminal
Figure 2-12 Connection of monitor
Cable Cover
Loosen two M4X10
pan-head screws.
Cable Entrance Plate
Unfasten three MX10
screws to remove cable
entrance plate.
Connect D-SUB
connector to J560
on the INTERFACE
Board.
Fasten ground wire with
M4X10 pan-head screw.
Unfasten top or bottom M4X10
pan-head screw fixing clamp plate.
Lay cable in clamp and then close
clamp plate.
CONNECTOR Board
INTERFACE Board
Fasten D-SUB connector
with screw.
1. Fasten cable
entrance
plate.
2. Close cable
cover.
3. Fasten ground
wire between
earth terminal
and ship's
superstructure.
2-9
CAUTION
Ground the equipment
to prevent electrical
shock and mutual
interference.