Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
Page 3
May 2012 Reference Manual replacement section. Brocade DCX 8510-4 Backbone Hardware 53-1002177-06 Clarified support for for shared Aug 2013 Reference Manual blades. Corrected FOS version required for certain blades. Corrected slot numbering order. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Brocade DCX 8510-4 Backbone (“Brocade DCX 8510-4”). This document presents information on setting up and operating the Brocade DCX 8510-4. It is organized in a loosely chronological order, beginning with an overview of the Brocade DCX 8510-4 and ending with removal and replacement procedures of field replaceable units (FRUs).
Supported hardware and software This document includes information specific to the Brocade DCX 8510-4 running Brocade Fabric OS version 7.0.0. and later. What’s new in this document The following information has been added: •...
NOTE A note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information. ATTENTION An Attention statement indicates potential damage to hardware or data. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
ID and password. White papers, online demonstrations, and data sheets are available through the Brocade website http://www.brocade.com/products-solutions/products/index.page For additional Brocade documentation, visit the Brocade website: http://www.brocade.com Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Serial console and Telnet session logs • syslog message logs 2. Brocade DCX 8510-4 serial number The Brocade DCX 8510-4 serial number (Switch Serial No.) and corresponding bar code are provided on the serial number label, as shown here: *FT00X0054E9* FT00X0054E9 The serial number label is located on the port side of the chassis, on the lower right side and directly above the cable management comb.
If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX 8510-4. For the Brocade DCX 8510-4, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis.
Two slots for control processor blades (CP8): A single active CP8 blade can control all 192 ports in the chassis. The standby CP8 blade assumes control of the Brocade DCX 8510-4 if the active CP fails. • Two slots for core switch blades (CR16-4): CR16-4 blade interconnects all port blades.
Page 23
QSFP-based inter-chassis link (ICL) cabling running at 64 Gbps (four 16 Gbps clustered in a single quad connector and cable). • Blades that are serviced from the port side of the Brocade DCX 8510-4. Blowers, power supplies, and power cables that are serviced from the nonport side. •...
NOTE Airflow in the Brocade DCX 8510-4 is from the nonport side to the left side and port side of the chassis (viewed from the port side) and out the exhaust vents. If you use the Port Side Exhaust Kit,...
Brocade DCX 8510-4 hardware components FIGURE 2 Port side of the Brocade DCX 8510-4 with the port side exhaust kit installed (sample configuration) Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
The following figure shows a sample configuration of the nonport side view of the Brocade DCX 8510-4. WWN card bezel (logo plate) Blower assembly (2x) Power supply (2x) Label with serial number and WWN FIGURE 3 Nonport side of the Brocade DCX 8510-4 (sample configuration) Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Fibre Channel port speeds. The blade also supports port-based in-flight encryption/decryption and compression/decompression. This port blade is compatible with the Brocade DCX 8510-8 and Brocade DCX 8510-4 and requires Fabric OS v7.0.0 or later to run in this chassis. 48-port 16-Gbps port...
CP failover activity, closes and flushes streams, provides flow control and message buffering, and supports a centralized active and standby state. Reliability The Brocade DCX 8510-4 uses the following error detection and correction mechanisms to ensure reliability of data: •...
• Bus monitoring and control of blades and other field-replaceable units (FRUs). Serviceability The Brocade DCX 8510-4 provides the following features to enhance and ensure serviceability: • Modular design with hot-swappable components. • Flash memory that stores two firmware images per control processor.
Brocade DCX 8510-4 shutdown, and the user interface Security The following list highlights some of the key security features available for the Brocade DCX 8510-4 and for other Brocade enterprise-class products running Fabric OS 7.0.1 or later. For details, contact your Brocade DCX 8510-4 supplier and refer to the Brocade White Paper, “The Growing...
E_Port disable Network manageability The Brocade DCX 8510-4 has a single domain and is managed as a single element with the Brocade Network Advisor. The Brocade DCX 8510-4 responds to its own IP address and appears as a separate entity to the Telnet protocol and SNMP.
Installing rack mount kit or 30 minutes Refer to the one or more of the following if you port side exhaust kit are mounting the Brocade DCX 8510-4 in a rack: Mounting and securing Brocade DCX 30 minutes Brocade Port Side Exhaust Kit Installation...
Page 35
8 rack units (8U) high. Plan to install the Brocade DCX 8510-4 with the nonport side facing the air-intake aisle. The Brocade DCX 8510-4 can be installed facing either direction, if serviceability and cooling requirements are met.
2. Use a pallet jack or other assisted lift to transport the new chassis to the installation area. Doorways must be wider than 36 in. (91 cm) to accommodate the chassis. 3. Remove the Brocade DCX 8510-4 port side exhaust kit (if ordered), accessory kit, packing foam, and antistatic plastic from the chassis and set aside.
RJ45-style connector. • Rack mount kit (as ordered) with instructions Order the Brocade-branded optical transceivers (SFP+, mSFP, and QSFP). The Brocade DCX 8510-4 supports SWL, LWL, and ELWL transceivers. The mSFPs and QSFPs are SWL transceivers only. NOTE...
Use of the high-voltage line (200 to 240 VAC) is highly recommended because of better power-conversion efficiency. For a fully-loaded DCX 8510-4, 200 to 240 VAC is required for high availability (ability to hot swap a failed power supply without affecting system operation).
Chassis slots are numbered 1 through 8, from bottom to top when facing the port side of the Brocade DCX 8510-4. Control processor blades (CP8) can be installed only in slots 4 and 5. Core switch blades (CR16-4) can be installed only in slots 3 and 6. The rest of the slots, 1, 2, 7, and 8, can be filled with port, application, or encryption blades.
Do not route the cables in front of the air exhaust vent, which is located at the top of the port side of the chassis.If you are using the Port Side Exhaust Kit with your Brocade DCX 8510-4, there is also an exhaust vent at the bottom of the port side of the chassis.
ISL Trunking group: eight ports marked with solid black ovals alternate with eight ports marked with oval outlines. Installing QSFP cables (optional) “Inter-chassis link (QSFP) cable removal and replacement” on page 88 for the procedure to install the QSFP cables Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
CP blade fails. The configuration information for the Brocade DCX 8510-4 is stored in the WWN cards and the flash memory of the CP blades. The configuration can be backed up to a workstation (uploaded) and then downloaded to the active CP blade if necessary.
Logging in to the serial console port 1. Verify that the Brocade DCX 8510-4 is powered on and that POST is complete by verifying that all power LED indicators on the port, control processor, and core switch blades display a steady green light.
– 10.77.77.74 / CP1 (the CP blade in slot 5 at the time of configuration) ATTENTION Resetting an IP address while the Brocade DCX 8510-4 has active IP traffic or has management and monitoring tools running, such as DCFM, Fabric Watch, and SNMP, can cause traffic to be interrupted or stopped.
Establishing an Ethernet connection to the Brocade DCX 8510-4 After using a serial connection to configure the IP addresses for the Brocade DCX 8510-4, you can connect the active CP blade to the local area network (LAN).
Customizing a switch name The switch name of the Brocade DCX 8510-4 can be up to 30 characters long using Fabric OS release 7.0.0 or later; can include letters, numbers, hyphens, and underscore characters; and must begin with a letter.
Setting the date To set the date, follow these steps. 1. If necessary, log on to the Brocade DCX 8510-4 by Telnet, using the admin account. The default password is password. 2. Enter the date command, using the following syntax: date "mmddHHMMyy"...
To synchronize the local time of the principal or primary switch with that of an external NTP server, follow these steps. 1. If necessary, log on to the switch by Telnet, using the admin account. 2. Enter the tsClockServer command: switch:admin> tsclockserver "<ntp1;ntp2>" Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Before connecting the Brocade DCX 8510-4 to the fabric, verify that the WWN Based persistent port identifier (PID) feature on the Brocade DCX 8510-4 matches the other switches in the fabric. This parameter must be identical for all switches in the fabric and is set using the configure command as shown in the following example: switch:admin>configure...
In this example, the license key is AAbbccDDeeFFeeGG. Keep a copy of the license key for reference. The 64-bit chassis ID is required to obtain and activate licenses for the Brocade DCX 8510-4. The chassis ID is available through the licenseIdShow command. The licenseShow and licenseIdShow commands must be entered on the active CP blade.
4. Verify the Brocade DCX 8510-4 and connector and port status using the switchShow -qsfp command. A sample of the command output is shown below. The example is from a DCX 8510-4 with a core blade installed in slot 3. Some details for the 8510-8 will be different, but the reported information for the QSFPs will be similar.
With the horizontal orientation of the blades in the Brocade DCX 8510-4, a pair of vertical cable management finger assemblies have been provided to keep the cables from hanging down in front of other blades.
This command provides information about switch and port status. 4. Verify the correct operation of the Brocade DCX 8510-4 in the fabric by entering the fabricShow command from the workstation. This command provides general information about the fabric.
NOTE It is recommended that the configuration be backed up on a regular basis to ensure that a complete configuration is available for downloading to a replacement Brocade DCX 8510-4. Powering off the Brocade DCX 8510-4 Perform the following steps to power off the Brocade DCX 8510-4.
DCX 8510-4. These commands are switchShow and chassisShow. Examples of these commands are shown below. Note in the switchShow command the new switchType for the Brocade DCX 8510-4 as well as the 16 Gbps speed identification for capable ports. The output has been truncated to reduce information duplication.
Page 59
No_SigDet ------ No_SigDet <output truncated> DCX-4_130:admin> Note in the chassisShow command the Chassis Family designation for the Brocade DCX 8510-4 along with specific information about every field-replaceable unit in the chassis. DCX-4_130:admin> chassisshow Chassis Family: DCX8510-4 Chassis Backplane Revision: 2...
Page 60
Header Version: Power Consume Factor: 2000 Factory Part Num: 23-0000067-01 Factory Serial Num: AGC2M03FR4P Manufacture: Day: Month: Year: 2010 Update: Day: 29 Month: Year: 2011 Time Alive: 229 days Time Awake: 0 days Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 61
Factory Part Num: 60-1000888-05 Factory Serial Num: ANQ0417F03P Manufacture: Day: Month: Year: 2010 Update: Day: 29 Month: Year: 2011 Time Alive: 229 days Time Awake: 0 days Chassis Factory Serial Num: ANP2523F00E DCX-4_130:admin> Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
The LED patterns may temporarily change during POST and other diagnostic tests. For information about how to interpret the LED patterns, see the table following the blade descriptions. 2. Check the blade status by entering slotShow. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
The FC8-64 port blade requires narrower OM-3 LC cables offered by major manufacturers like Corning, Molex, and Amphenol. Status LED Fibre Channel port Power LED Port Status LED FIGURE 7 FC8-32E port blade Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Determining the status of a port or application blade Status LED Fibre Channel port Power LED Port Status LED FIGURE 8 FC8-48E port blade Status LED Fibre Channel port Power LED Port Status LED FIGURE 9 FC16-32 port blade Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Determining the status of a port or application blade Status LED Fibre Channel port Power LED Port Status LED FIGURE 10 FC16-48 port blade Status LED Fibre Channel port Power LED Port Status LED FIGURE 11 FS8-18 encryption blade Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Port status LED for 10GbE port 0 GbE (GE) port 6 Port map Port status LED for GbE port 6 FIGURE 12 FX8-24 extension blade “FX8-24 blade” for information about trunking groups on this blade. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
2 is faulty. If LED continues to flash, seconds) replace the blade. Fast-flashing amber (on Environmental range exceeded. Check for out-of-bounds 1/2 second, then off 1/2 environmental condition and second) correct it. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 68
Port is online, with traffic No action required. flowing through port. Fast-flashing amber Transceiver or port is faulty. Change the transceiver or reset (on 1/4 second, then the switch from the workstation. off 1/4 second) Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Recommended action Power Steady green CP blade is on. No action required. No light (LED is off) CP blade is not on. Ensure that the blade is firmly seated and has power. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
POST and other diagnostic tests. For information about how to interpret the LED patterns, refer to Table 2. Check the core switch blade status by entering slotShow and haShow. Figure 14 identifies the core switch blade. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
LED continues to flash, replace the blade. Fast-flashing amber (on 1/2 Environmental range Check for out-of-bounds second, then off 1/2 second) exceeded. environmental condition and correct it. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
The power supply status displays OK, Absent, or Faulty. If a power supply displays absent or faulty, contact the Brocade DCX 8510-4 supplier to order replacement parts. Both physically absent or faulty could also be the result of the power supply not being properly seated or being turned off.
If a blower assembly displays absent or faulty, contact the Brocade DCX 8510-4 supplier to order replacement parts. Both physically absent or faulty could also be the result of the power supply not being properly seated.
EM-I2C_TIMEOUT, 2, WWN 1 I2C timed out: state 0x4 WWN unit fails to power on <timestamp>, [EM-1004], <sequence-number>,, CRITICAL, <system-name>, WWN # failed to power on <timestamp>, [EM-1043], <sequence-number>,, WARNING, <system-name>, Can't power <FRU Id> <state (on or off)>. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Chassis door removal and replacement NOTE The chassis door must be installed to ensure the Brocade DCX 8510-4 meets EMI and other regulatory certifications. Additionally, if ICL cables are not used, EMI plugs must be inserted in the ICL cable ports to meet certification standards.
The Brocade DCX 8510-4 comes equipped with two vertical cable management finger assemblies. It can continue to operate during the replacement of the cable management fingers. Due to the horizontal orientation of the blades in the Brocade DCX 8510-4, the finger assemblies are attached to the uprights of the mounting rack. See Figure 19 for this procedure.
Port, application, and encryption blade removal and replacement This section describes how to remove and replace port, application, and encryption blades. It does not cover the core (CR) blades or the control processor (CP) blades. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Slots are numbered from 1 through 8, from bottom to top when facing the port side of the Brocade DCX 8510-4. Port, application, and encryption blades can be installed in slots 1-2 and 7-8. Time and items required The replacement procedure for each blade takes less than 10 minutes.
Page 82
FS8-18 encryption blade: Open the ejectors by rotating them toward the center of the blade face. Pull the blade out of the chassis using the ejectors. 12. If the blade is not being replaced by another blade, install a filler panel. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
For FC8-64, FC8-32E, FC8-48E, FC16-32, FC16-48 port blades, FX8-24 application blade, and FS8-18 encryption blade: Close the ejectors by rotating them away from the center of the blade. The levering action of the ejectors seats the blade in the slot. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
1. Remove the chassis door. 2. Unscrew the thumbscrews on the panel using the Phillips screwdriver. 3. Using the tabs, pull the filler panel out of the chassis. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Control processor blade (CP8) removal and replacement This document describes how to remove and replace a control processor (CP8) blade. Each chassis has two CP8 blades. In the DCX 8510-4 they are located in slots 4 and 5. NOTE The CP8 blade is compatible only with the Brocade DCX Backbones (including the 8510s).
NOTE For the DCX 8510-4, slots are numbered from 1-8 from bottom to top, viewed from the port side of the chassis. There are several references to additional Brocade manuals in this document. To access them online, go to this location on the MyBrocade web site, http://my.brocade.com/wps/myportal/!ut/p/c1/04_SB8K8xLLM9MSSzPy8xBz9CP0os3gnN8cwY...
If automatic failover has not occurred, manually failover the faulty blade by moving the slider to the off position (to the right in a DCX 8510-4). Then power off the faulted blade, log in to standby CP blade, and skip to step 7.
Enter information at the prompts. a. Run the fosconfig --show command to determine if virtual fabrics are enabled. If so, run the configupload -vf command. This command uploads the Brocade DCX 8510-4 virtual fabric data. b. If virtual fabrics are not enabled, run the configupload command. This command uploads the Brocade DCX 8510-4 configuration.
Once you have installed the replacement CP blade, see “Verifying operation of the new CP blade” for information about determining the version of firmware on the replacement CP blade and upgrading it if necessary. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
NOTE The DCX 8510-4 requires Fabric OS 7.0.0 or later to be recognized. If the firmware on the replacement blade is earlier than 7.0.0 it must be brought up to the version on the active CP blade, which must be at least 7.0.0.
INIT: Switching to runlevel: 6 INIT: Sending processes the TERM signal DCX_124:admin> HAMu Heartbeat down, stop FSS Unmounting all f##exiting due to signal: 9, pending signals: 0x20000, 0x0 ilesystems. Please stand by while rebooting the system... Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 92
The firmware folder contains the folder for the specific release you are installing. 1. Insert the USB device into the active CP blade. 2. Attach a serial cable from the PC to the active CP blade. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 93
2010/06/18-14:56:50, [SULB-1002], 910, SLOT 7 | CHASSIS, INFO, Brocade_DCX, Firmwaredownload command has completed successfully. NOTE The time stamp on the co-cpu may not be in sync with the main cpu on the blade. This is not a cause for concern. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
3. Type firmwareShow to verify that the firmware version has been updated and that the versions are the same on the two CP blades. The slot numbers will be different for the DCX 8510-4 or DCX-4S. (not all slot numbers are shown) DCX_8510:admin>...
For more information about error messages, refer to the Fabric OS Message Reference. Removing a core switch blade (CR16-4) The Brocade DCX 8510-4 continues to operate while a core switch blade is being replaced. Refer to Figure 23 for the following procedure.
ATTENTION Follow ESD precautions. NOTE The CR16-4 blade is compatible only with the Brocade DCX 8510-4. 1. Remove the chassis door. Unscrew the two thumb screws from the ejectors on the blade using the Phillips screwdriver. Unscrew the left thumb screw until it pops out. This initiates a hot-swap request.
The Brocade DCX 8510-4 can continue operating during the replacement if the second 220 VAC power supply is operating. If the Brocade DCX 8510-4 is supplied with 110 VAC (nominal), there is a risk of some blades being powered off for lack of power during the replacement.
1. Perform the appropriate following action based on whether the Brocade DCX 8510-4 is operating: • If the Brocade DCX 8510-4 is not operating during the replacement procedure, go to step • If the Brocade DCX 8510-4 is operating and will continue to operate during the replacement, check the power LEDs to verify that the minimum number of power supplies is functioning.
6. Turn on the power switch. Verify that the power LED on the power supply displays a steady green light. Blower assembly removal and replacement Use this procedure to remove and replace a blower assembly. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Blower assembly removal and replacement ATTENTION The Brocade DCX 8510-4 can continue operating during the replacement if the second blower assembly is operating, To ensure continuous adequate cooling, maintain two operating blower assemblies at all times except for the brief period when replacing a blower assembly.
Use this procedure to remove and replace a WWN card. NOTE The World Wide Name (WWN) cards contain fully redundant circuits and normally do not require replacement. Two WWN cards are located beneath the WWN bezel (logo plate). Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Figure When the replacement WWN card has been received, complete the following steps to remove the bezel and faulted WWN card. ATTENTION Follow ESD precautions (see “ESD Precautions” in your chassis manual). Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Removal and replacement of the WWN bezel (logo plate) and WWN card ‘ Replacing the WWN card and WWN bezel (logo plate) For the following procedure, please refer to Figure Complete the following steps to replace the bezel and WWN card. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Most Brocade switches and backbones come with a transceiver extraction tool (Figure 1) and holster. The extraction tool is designed to remove transceivers from switches and blades where the space is limited. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
16 Gbps SFP+ from the switch or blade. See the illustration for the mSFP transceiver for the basic appearance of the 16 Gbps transceiver. Bail FIGURE 29 Replacing an optical transceiver Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Use this procedure to remove and replace mSFP transceivers. Do not use the extraction tool to remove the transceivers. NOTE The mSFP transceivers are used only with the FC8-64 port blade. Narrower OM-3 LC cables are used to connect the FC8-64. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
1. Insert the cable into the new transceiver until the latching mechanism clicks. 2. Position the optical transceiver so that the key is oriented correctly to the port. Insert the transceiver into the port until it is firmly seated and the latching mechanism clicks. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Full link is established. Follow this procedure to install the QSFP cables. Refer to the Fabric OS Administrator’s Guide for the configuration procedure and requirements. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
This provides for inter-chassis link (ICL) trunking between chassis, ensuring redundancy. Parallel connections between core blades are recommended. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
8510-8. The cabling scheme should follow the parallel example shown in the Figure 34. Each line in the example actually represents four cables running between the chassis. FIGURE 35 DCX 8510 core/edge ICL topology Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
FIGURE 36 DCX 8510 full mesh ICL topology Brocade DCX 8510-4 chassis removal and replacement This section describes how to remove and replace the Brocade DCX 8510-4 chassis (with its backplane). The basic steps are: Faulty Brocade DCX 8510-4 chassis indicators...
Reconnecting the system to the network and fabric Verifying correct configuration of the fabric NOTE The Brocade DCX 8510-4 must be removed from the fabric and powered off to perform this procedure. Contact your support provider if you have any questions about whether the chassis requires replacement.
New factory serial number New serial number (if available) 1. Open a Telnet session and log in to the Brocade DCX 8510-4 as admin. The default password is password. Enable the logging function on your Telnet or serial console connection.
Page 116
• Enter configUpload -all; then enter the requested information at the prompts. This command uploads the Brocade DCX 8510-4 configuration to the customer-defined FTP server, making it available for downloading. For more information about this command, refer to the Fabric OS Command Reference.
Page 117
-qsfp • fabricShow Copy the command output into a text file named “SANbefor.txt.” After the Brocade DCX 8510-4 is restored to the fabric, this information can be used to verify that no unintentional changes have occurred to the fabric.
This file provides a backup of all the information that might be required by Technical Support. The information can be used after the Brocade DCX 8510-4 is restored to the fabric to verify that no unintentional changes have occurred to the fabric.
NOTE If the Brocade DCX 8510-4 is installed in a cabinet, ensure that the cabinet is balanced and secured mechanically and that the removal and installation procedure will not compromise cabinet stability.
The Brocade DCX 8510-4 performs a power-on self-test (POST). The POST takes a minimum of three minutes and is complete when LED activity returns to standard state. 12. Verify that the Brocade DCX 8510-4 is powered on and POST is complete (all power LED indicators on the blades should be a steady green).
The configDownload command can be entered through a Telnet or serial session, but the Brocade DCX 8510-4 must have an Ethernet connection to the server name or IP address of the host for the download process to complete.
SW BLADE FC16-48 ENABLED SW BLADE FC8-64 ENABLED switch:admin> 3. Verify that the Brocade DCX 8510-4 is functioning correctly by entering switchShow or switchStatusShow. This switchShow command displays the Brocade DCX 8510-4 and port status information. DCX-4_130:admin> switchshow switchName: DCX-4_130 switchType: 121.3...
The Brocade DCX 8510-4 can be accessed by remote connection using any of the available management tools, such as Telnet or Web Tools. Ensure that the Brocade DCX 8510-4 is not modified using other connections during the rest of this procedure.
• ISL and port states • Number of switches in the fabric 3. Resolve any issues or unintentional changes to the Brocade DCX 8510-4 or fabric: • If there are any mechanical problems, try reseating the associated component. • If the configuration information is not correct for the Brocade DCX 8510-4, modify as required.
64-port template for a cable routing table. Make copies of the table to cover the total number of ports in the Brocade DCX 8510-4. TABLE 12 Cable routing table for Brocade DCX 8510-4 (64 ports shown) Slot/port Cable labels...
Environmental regulation compliance ......121 General specifications The Brocade DCX 8510-4 is compliant with United States and International safety and Electromagnetic Compatibility (EMC) standards.
An aggregate switching capacity of 3.36 billion frames per second (for Class 2, Class 3, and Class F frames for a 192 port chassis System architecture Table 14 describes the system architecture of the Brocade DCX 8510-4. TABLE 14 System architecture Feature...
Chassis-to-chassis linkage through connectors on the core switch blade (CR16-4). (ICL/QSFP) System size and weight The weight of the Brocade DCX 8510-4 can vary considerably depending on the combination of blades installed. Use Table 15 and the system FRU weights table to determine the weight of the Brocade DCX 8510-4 with your combination of port and application blades.
Facility requirements Facility requirements The facility where the Brocade DCX 8510-4 is in use must meet the following requirements to provide for correct operation: • Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the chassis nameplate.
Watch commands to view temperature status. Fibre Channel port specifications The Fibre Channel ports in the Brocade DCX 8510-4 support full duplex link speeds at 2, 4, 8, 10, or 16 Gbps inbound and outbound, automatically negotiating to the highest common speed of all devices connected to the port.
Page 133
12 8 Gbps SFP+ up to 4 48 8 Gbps blade 10 1 Gbps Ethernet 40 1 Gbps Ethernet 2 10 Gbps Ethernet 8 10 Gbps Ethernet Fan unit 2 fans per chassis Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
In addition to these tables, you can consult the power tables in the latest update of the Fabric OS Release Notes. Power cords The types of power cords provided with the Brocade DCX 8510-4 are specific to the country where it is installed. For each of the types of power cords in Table 21, the end that connects to the Brocade DCX 8510-4 has an IEC 60320/C19 cable connector.
Page 135
Czech, Rep. of Denmark Egypt England Finland France Germany Greece Hong Kong Hungary India Indonesia Ireland, North Ireland, South Israel Italy Japan Korea, South Malaysia Alternate Recommended Mexico Monaco Netherlands New Zealand Norway Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Emirate United Kingdom United States Venezuela Yugoslavia Power-cord notice CAUTION This switch might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
(D004), at the end of each notice. Use this ID to locate the translations of these danger and caution notices in the Brocade Product Safety Notices. Regulatory compliance This section describes the regulatory compliance requirements for the Brocade DCX 8510-4. It contains the following standards: •...
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations, ICES-003 Class A. German statement Maschinenlärminformations-Verordnung – 3 GPSGV, der höchste Schalldruckpegel beträgt 79.0 dB(A) gemäss EN ISO 7779. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
IEC 825-2. Optical products that do not comply with these standards might emit light that is hazardous to the eyes. Regulatory compliance standards The following table lists the regulatory compliance standards for which the Brocade DCX 8510-4 is certified. TABLE 24...
The EPUP assumes that the product will be used under normal conditions in accordance with the operating manual of the product. (EPUP) EPUP Brocade Brocade ocade EPUP Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 143
Information products (Decree No. 39 by the Ministry of Information Industry), the following information is provided regarding the names and concentration level of hazardous substances (HS) which may be contained in this product. Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
FX8-24 blade ..........126 Introduction This appendix provides details about the application and encryption blades that are available optionally for the Brocade DCX 8510-4. Contact your Brocade DCX 8510-4 supplier for additional information. FS8-18 blade...
Ten per trunk through the 10 GbE ports. • SO-TCP with reorder resistance. • FastWrite over FCIP. • Tape pipelining over FCIP. • FICON XRC emulation and tape pipelining over FCIP (licensable). • FICON CUP (licensable). Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 147
Administrator’s Guide. • Up to three FC trunking groups. The three groups are defined as: Trunk group 0: FC ports 0,1 Trunk group 1: FC ports 6,7 Trunk group 2: FC ports 2,3,4,5,8,9,10,11 Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
In addition, a number of managing and monitoring features are available, such as Fabric Manager, Web Tools, Fabric Watch, and Advanced Performance Monitoring. If the Brocade DCX 8510-4 does not operate as expected, the following steps can be taken to diagnose the problem: •...
Interpreting POST and boot results The Brocade DCX 8510-4 performs Power On Self Test (POST) by default each time the chassis is powered on, rebooted, or reset. The Brocade DCX 8510-4 can be rebooted using the reboot (to reboot each CP individually) or fastBoot commands.
1. Universal port configuration is performed. 2. Links are initialized. 3. Fabric is analyzed. If any ports are connected to other switches, the Brocade DCX 8510-4 participates in a fabric configuration. 4. The Brocade DCX 8510-4 obtains a domain ID and assigns port addresses.
9600 bits per second, 8 databits, no parity, 1 stop bit, no flow control. Serial port might be incompatible (only Ensure that the Brocade DCX 8510-4 is connected to RS-232 is supported). an RS-232 port. RS-423 serial ports might experience difficulties due to corner-case incompatibilities of the standards.
Page 153
Replace the parts as required. None of the LEDs on a component Component might not be seated correctly. Ensure that the Brocade DCX 8510-4 has power and are on. the component is firmly seated. If the problem continues, enter the sensorShow command to determine the component status.
Enter the tempshow and sensorShow command to determine the component status. If the component is a CP blade or port blade, enter the slotShow command to determine the status. Replace the component as necessary Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Appendix Port Numbering Template Print or copy the following templates in this appendix and use them to document the port numbering pattern for the Brocade DCX 8510-4. These templates show the following blades: • FC16-4 core blade (Figure • FC8-64 high density port blade (Figure •...
FC ports 24-31 FC ports 8-15 Port and trunking group map FIGURE 39 FC8-32E port blade Blade Power LED FC ports 24-47 Blade Status LED FC ports 0-23 FIGURE 40 FC8-48E port blade Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 160
FCC warning (US only) troubleshooting FCIP verifying operation features, software CR blade Fibre Channel determining status removing port specifications replacing Fibre Channel Association xvii Fibre Channel Routing Services Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 161
WWN bezel laser compliance replacing latency WWN card port to port replacing switch FS8-18 blade LEDs FX8-24 blade blower assembly CP blade CR blade port blade power supply GbE ports troubleshooting Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 162
LEDs serial connection replacing establishing status troubleshooting power, providing serial port logout protocol, ANSI serviceability, features setting time zone Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Page 163
WWN card tasks, installation determining status template, port numbering error messages terminal emulator, configuring preparing for replacement tool, extraction, transceivers replacing trademarks verifying need to replace transceivers extraction tool QSFP replacing supported types Brocade DCX 8510-4 Backbone Hardware Reference Manual 53-1002177-06...
Need help?
Do you have a question about the DCX 8510-4 and is the answer not in the manual?
Questions and answers