Download Print this page
Furuno FAR2XX7 Series Configuration Manual
Furuno FAR2XX7 Series Configuration Manual

Furuno FAR2XX7 Series Configuration Manual

Configuring the far2xx7 series radar for use with maxsea time zero

Advertisement

Quick Links

Configuring the FAR2XX7 Series Radar
for use with MaxSea Time Zero
Introduction
In order to operate with MaxSea Time Zero AND NavNet3D, the FAR2XX7's processor
software must be version 02.5x.
If you plan to connect one or multiple FAR2XX7(s) directly to MaxSea Time Zero
without NavNet3D, you can use version 02.5x or version 03.xx
To check the software version of the FAR2XX7, perform the following steps:
Press or left click MENU, then 9-8-2-2 (SELF TEST)
Version number
is shown here
If a radar software change is required, check the appropriate product pages' documents
section at
www.furuno.com
for the correct procedures.
Check and Assign Radar Hostname(s):
When multiple radars are networked or inter-switched together, a unique number must be
assigned to each processor. Note that for MaxSea to correctly detect the radar, one
FAR2xx7 must be assigned to "RADAR1" (IP address = 172.31.3.6).
To assign the radar a number, hold "HL OFF" and press the "MENU" key 5 times. The
"Initialize" menu will appear. Select "Installation" (4), then Radar NO (4). You may also
want to set-up the Radar Antenna Position (5). Once the radar number is changed, the
radar must be powered down and then turned back on to store the new setting. If
applicable, follow the same procedure for each radar in the network, and then confirm
that each radar number is unique. You cannot have two radars on the same network with
the same name.
Note: Whenever a network change is made, it is recommended that all radars are
powered down and restarted.
To confirm the network settings and communications between multiple radars, power up
all of the radars in the network, then right click on the Radar Antenna box (top left
corner). The antenna information for all of the available radars in a network will appear
on the right in the menu panel. Be sure that all the radars on the network are all listed in
this panel. If not, check the cables and the network settings.

Advertisement

loading

Summary of Contents for Furuno FAR2XX7 Series

  • Page 1 In order to operate with MaxSea Time Zero AND NavNet3D, the FAR2XX7’s processor software must be version 02.5x. If you plan to connect one or multiple FAR2XX7(s) directly to MaxSea Time Zero without NavNet3D, you can use version 02.5x or version 03.xx...
  • Page 2 Setup the Computer’s IP address: You will have to assign a manual IP address to the computer (usually 172.31.3.150). This IP must be unique and not already taken by another computer on the network. To set up an IP address, open the Windows “Control Panel.” Open “Network Connections.”...
  • Page 3 Select “Internet Protocol (TCP/IP)” and click on “Properties.” Note: Under Vista/7 select “Internet Protocol Version 4” as shown below Fill the IP fields as shown below: Click on OK to confirm the change. The new IP can take up to 20 seconds to be recognized.
  • Page 4: Navigation Information

    If MaxSea is directly connected to one or multiple FAR2xx7: One FAR2xx7 can be set up to output Position, COG and SOG on the network. From the FAR2xx7 that has a GPS connected to it (serially), right click on the “Own Ship Position”...
  • Page 5 Select the Network Adapter corresponding to the computer IP address then type “10028” for the UDP port. Note: If you acquire an ARPA target on the FAR2xx7, you should see $TTM sentences flow in the window. Click on “Next”. When MaxSea is done analyzing the port, the following window will...
  • Page 6 Click on “Next” then “Finish” to finalize the configuration...