Donotmodifytheplugprovided withtheappliance. If it will 8. Properly s ecure power c ordto strainrelief.
notfit theoutlet, h ave a proper outletinstalled by a quail-
9. Reinstall the cover.
fled electrician.
CONNECTING
APPLIANCE
USING
A 4-WIRE
CORD
WITH
PLUG (MUST BE USED FOR MOBILE
HOME
INSTALLATION)
NOTE: Since January
1, 1996, the National
Electric code re-
quires that the new constructions
utilize a 4-wire
connection
to an electric
dryer.
NEVER LEAVE THE COVER OFF OF THE TER-
MINAL
BLOCK.
CONNECTING
APPLIANCE
USING
A 3-WIRE
CORD
WITH
PLUG
Only a 4-conductor
cord shall be used when the appli-
ance is installed in a location where grounding
through
the neutral conductor
is prohibited.
Grounding
through
the neutral is prohibited
for the new branch-circuit
in-
stallations,
mobile homes, recreational
vehicles, and ar-
eas where local codes prohibit
grounding
through the
neutral conduction.
Remove
ground
strap
and
discard.
Keep
green
Hot
_1_
ground
screw
_%
_b
wire
Relocate
green
ground
screw
here
Green
or
• _
/ yellow
wire
Strain
bracket
Cover
3/4- uL
/
Hot
recognized
Wire
strain
relief
/
4 #10
AWG
minimum
copper
conductors
or 120/240
V 30 A power
supply
cord
kit marked
for
use
with
dryers
& provided
with
closed
loop
or spade
terminals
with
upturned
ends
(not supplied)
1. Turn off the circuit
breaker
(s) (30 amp) or remove the
dryer's circuit fuse at the electrical
box.
2. Be sure the appliance
cord is unplugged
from the wall re-
ceptacle.
3. Remove the power cord cover located
at the lower back.
4. Remove and discard
ground strap. Keep the green ground
screw for step 7.
5. Install 3/4
in. UL recognized
strain relief to power cord
entry hole. Bring power cord through
strain relief.
6. Connect
power cord as follows:
A. Connect
the 2 hot lines to the outer screws of the termi-
nal block (marked
L1 and L2).
B. Connect the neutral
(white) line to the center of the ter-
minal block (marked
N).
7. Attach
ground wire of power cord with the green ground
screw (hole above strain relief bracket).
Tighten all termi-
nal block screws (3) completely.
Green
Ground
Ground
Screw
Hot
L_
Wire
Strain
Relief
Bracket
3/4"
UL
Recognized
train
Relief
Neutral
(White)
Hot
Wire
Cover
3 #10
AWG
minimum
copper
conductors
or 120/240
V 30
A power
supply
cord
kit marked
for
use
with
dryers
& provided
with
closed
loop
or spade
terminals
with
upturned
ends
(not supplied)
1. Turn off the circuit breaker(s)
(30 amp) or remove the
dryer's circuit fuse at the electrical
box.
2. Be sure the appliance
cord is unplugged
from the wall.
3. Remove the power cord cover located
at the lower back.
4. Install 3/4
in. UL recognized
strain relief to power cord
entry hole. Bring power cord through
strain relief.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the termi-
nal block (marked
L1 and L2).
B. Connect the neutral (white)
line to the center of the ter-
minal block (marked
N).
6. Be sure ground strap is connected
to neutral
(center) ter-
minal of block and to green ground
screw on cabinet
rear.
Tighten all terminal
block screws (3) completely.
7. Properly
secure power cord to strain relief.
8. Reinstall the cover.
NEVER LEAVE THE COVER OFF OF THE TER-
MINAL
BLOCK.