Kenmore 3405586 Owner's Manual page 24

29-inch wide electric dryers
Table of Contents

Advertisement

ROUTE
THE VENT
Typical installations
exhaust from the
rear of the dryer.
Avoid
pushing
the dryer tightly
against
a wall. This can crush or kink the vent.
Use the straightest
path you can, where
possible.
Avoid
90 ° turns.
Rear exhaust installations
for standard
offset connections
- (see pgs. 25-26)
Rear exhaust installations
for offset
connections
with close clearances
-
(see p. 27)
24
DETERMINE
VENT
LENGTH
Maximum
Exhaust
Lengths:
• The maximum
length
of the rear
exhaust
system
depends
on the
type of vent,
the number
of elbows,
and the type of exhaust
hood.
Refer
to the chart
below.
NOTE:
If a combination
of rigid metal
vent
and flexible
metal vent is used,
use instructions
for flexible
metal vent.
4-INCH
EXHAUST
HOODS
Number
Maximum
length of
of 90 °
4-inch diameter
rigid
Turns
heavy metal vent
0
64 ft.
1
54 ft.
2
44 ft.
3
35 ft.
4
27ft.
Number
Maximum
length of
of 900
4-inch diameter flexible
Turns
heavy metal vent
0
36 ft.
1
31 ft.
2
27 ft.
3
25ft.
4
23ft.
21/2-INCH
EXHAUST
HOODS*
Number
Maximum
length of
of 900
4-inch diameter
rigid
Turns
heavy metal vent
0
58 ft.
1
48ft.
2
38 ft.
3
29ft.
4
21ft.
Number
Maximum
length of
of 900
4-inch diameter flexible
Turns
heavy metal vent
O
28ft.
1
23ft.
2
19ft.
3
17ft.
4
15ft.
*Use a 4-inch exhaust hood if possible.