IV. FOUR-WIRE ELECTRICAL
CONNECTION
(DIRECT WIRE)
Prepare
cable
as directed:
Fire Hazard
Use 10 gauge solid copper wire,
Use a UL approved strain relief,
Disconnect
power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal
(silver).
Ground wire (green or bare wire)
must be connected to green ground
connector.
Connect remaining 2 supply wires
to remaining
2 terminals
(gold).
Securely tighten all electrical
connections,
Failure to follow these instructions
can result in death, fire, or electrical
shock,
The dryer can be connected
directly
to
fused
disconnect
or circuit
breaker
box
with four-wire
flexible
armored
or non-
metallic
sheathed
copper
cable
(with
grounding
wire). All current-carrying
wires
must be insulated.
The grounding
wire
may be bare.
A conduit
connector
must
be installed
at
junction
box. Allow four feet of slack in the
line so dryer can be moved
if servicing
is
ever necessary.
GROUNDING
INSTRUCTIONS
This appliance
must
be connected
to
a grounded
metal,
permanent
wiring
system;
or an equipment-grounding
conductor
must
be run with the circuit
conductors
and connected
to the
equipment-grounding
terminal
or
lead on the appliance.
STEP
1. Disconnect
power.
STEP
la.
Strip 5 inches
of outer
covering
from end of cable.
Leave
bare grounding
wire at 5 inches.
5"_
I
STEP
lb.
Cut 11/2 inches
from the
three
remaining
insulated
wires.
Strip
insulation
back 1 inch. Shape
the end
of each wire into a "U" shaped
hook.
STEP 2. Remove hold-down screw
and terminal block cover.
H01d-d0wnscrew
Terminal block cover
21