Furuno FCV-30 Operator's Manual page 59

Furuno color sounder operator's manual model fcv-30
Hide thumbs Also See for FCV-30:
Table of Contents

Advertisement

Item
Picture
Show current picture advance setting.
advance
Shift
Show current shift value.
Alarm
Show current alarm content.
Gain
Show current gain setting.
Choose Marker line from the menu bar and push the left button. The timer
Timer
then counts up the number of minutes (max. 99 min. 59 sec.) since the left
button was pushed.
Water temperature data, fed from external temperature sensor, is shown.
Temperature
Temperature range: -99.9°C to 99.9°C
Position data, fed from a navigator, is shown.
Latitude and longitude range:
L/L
Latitude: 90°00.000'S to 90°00.000'N
Longitude: 180°00.000'W to 180°00.000'E
Speed, fed from speed log, is shown.
Speed
Speed range: 0.0 kt to 99.9 kt
Course, fed from a navigator, is shown.
Course
Course range: 0°-359°
Roll angle, fed from appropriate sensor, is shown.
Roll
Roll angle range: -90.0° to 90.0°
Pitch angle, fed from appropriate sensor, is shown.
Pitch
Pitch angle range: -90.0° to 90.0°
Heave, fed from a satellite compass, is shown.
Heave
Heave range: -99.m to 99.0 m
Range and bearing to a TO waypoint, fed from a navigator, is shown.
Range/Bearing
Range and bearing: 0°-360°
Time
Time difference, fed from a Loran C navigator, is shown
difference
Time difference range: 00000.0 to 99999.9
Draft
Draft calibration method is shown; below surface or below transducer.
Data display description
Description
2. WINDOW DISPLAYS
2-5

Advertisement

Table of Contents
loading

Table of Contents