Heat Operation - Mitsubishi Electric MUH-GA35VB Service Manual

Split-type, heat pump air conditioners, wireless type models
Hide thumbs Also See for MUH-GA35VB:
Table of Contents

Advertisement

HEAT operation

Condition indoor:Dry bulb temperature 20.0°C
Wet bulb temperature 14.5°C
MUH-GA20VB -
5
4
230V
3
2
5
7
10
15
20
Ambient temperature(˚C)
MUH-GA35VB -
6
230V
5
4
3
5
7
10
15
20
21
Ambient temperature(˚C)
Outdoor:Dry bulb temperature 7,15,20°C
E1
21
25
(:)
E1
(:)
25
14
Wet bulb temperature 6,12,14.5°C
MUH-GA25VB -
5
4
3
2
5
7
10
15
20
Ambient temperature(˚C)
E1
230V
(:)
21
25

Hide quick links: