8. MAINTENANCE

8-1. Address Setting of the Remote
Control Unit
The address can be set in order to prevent interfer-
ence between remote controllers when two Sanyo
indoor units are installed near each other. The address
is normally set to "A." To set a different address, it is
necessary to change the address on the second
remote controller.
NOTE
Once changed, you cannot restore the original
address setting of the air conditioner.
(1) Switch on the power source.
(2) Break the address-setting tab marked "A" on the
second remote controller to change the address
(Fig. 13). When the tab is removed, the address is
automatically set to B (Fig. 14).
(3) Press and hold the remote controller QUIET but-
ton and 1 HR TIMER button. At the same time,
press the ACL (reset) button. Use a thin object
such as the tip of a pen to press the ACL button.
When this has been done, "oP-1" (test run)
appears, blinking, in the remote controller clock
display area.
(4) Each time the 1 HR TIMER button is pressed, the
display changes as shown below. Press this but-
ton 2 times to change the display to "oP-7"
(address setting). (Fig. 15)
Test run mode
Self-diagnostic mode
Address setting mode
(5) "oP-7" has now been selected for address setting.
(6) Press the ON/OFF operation button on the remote
controller. (Fig. 15) Check that the "beep" signal-
received sound is heard from the second indoor
unit (approximately 5 times). The sound you hear
is the signal that the remote controller address
has been changed.
(7) Finally press the remote controller ACL (reset)
button to cancel the blinking "oP-7" display.
(Fig. 15)
Changing of the second remote controller address is
now completed.
QUIET
button
32
Tab
Fig. 13
ACL button
Fig. 14
AIR CONDITIONER
ON•/OFF•
UIET
1HR.
TEMP.
MODE
FAN SPEED
NIGHT SETBACK
FLAP
HIGH POWER
TIMER
CANCEL
CLOCK
SENSOR
F
12H
24H
ADR
ACL
Fig. 15
ON/OFF
operation
button
1HR.
TIMER
button
ACL
(Reset)
button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-crv93ehSap-krv93ehSap-crv123eh

Table of Contents