Kenmore Gas Dryer 110.7506 Use & Care Manual page 6

Table of Contents

Advertisement

Available languages

Available languages

Dryer Dimensions
*Most installations require a minimum 51/2"(14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area or closet
installation
The dimensions
shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
,
_
(310 c #_H
(42.87
;i?
I_ I(_._,cm
24N=_
--
--_
._
(15_0¢n }1
(2.6cm)
(6&6cr[1)
{2.5cm} (2.5cm) {74acre} (14cm)
Companion appliance spacing should also be considered.
"_ 3"
(7=6 cm)
NN-
A
B
C
"_
3"
(7.6 cm)
7
A, Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Mobile Home
- Additional
Installation
Requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile home installations require:
Metal exhaust system hardware which is available for
purchase from your local Sears store or Sears Service dealer.
Mobile Home Installation Kit Part Number 346764. See "Tools
and Parts" section for ordering information.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Emectrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Faimure to follow these instructions
can result in death,
fire, or emectrica{ shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is also recommended
that a separate circuit
serving only this dryer be provided.
GROUNDING
mNSTRUCTIONS
" For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding wilI reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
SAVE THESE
INSTRUOTmONS

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Elite sensor smart 110.7506 series

Table of Contents