Stepping Motor Driving(12)
9
10
MICOM
11
12
DESCRIPTION
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.
It is driving as following Fig 12-1. (Ring Count Method of 8 Status)
Ø 4
Ø 3
Ø 2
Ø 1
(Normal Rotating)
12V
CN11
1
IC4
2
3
4
5
6
KID65004
Fig 12-1
31
B +
Ø 1
M1
Ø 2
FOR SWING
Ø 3
Ø 4