PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE
INSTALLING AND OPERATING THE UNIT:
This air conditioner meets strict safety and operating
standards. The installer of this unit must install or service
this unit so it operates safely and efficiently.
IMPORTANT NOTES
• Adhere to all safety instructions and warnings
throughout this manual.
• Read this manual carefully before installing or operat-
ing this unit to become familiar with its features and
obtain the performance that will bring you continued
enjoyment for many years.
• Follow each installation or repair step exactly as
shown in the manual.
• Observe all local, state and national electric codes.
Contact your local government for more information
on electrical codes.
The lightning flash with arrowhead symbol,
within an equilateral triangle is intended to
alert the user to the presence of uninsulat-
ed dangerous voltage within the product's
enclosure that may be of sufficient magni-
tude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and main-
tenance (servicing) instructions in the liter-
ature accompanying the appliance.
Contact Installer if Necessary:
The installation instructions are for a experienced
installer. If you are not an experienced installer, contact a
local installer for help. If you require help with service,
contact your certified dealer or Daewoo Electronics for
additional instructions.
If Unit is Installed Improperly:
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this manual.
WARNING:
• ELECTRICAL SHOCK CAN CAUSE SEVERE PERSON-
AL INJURY OR DEATH. ONLY A QUALIFIED, EXPERI-
ENCED ELECTRICIAN/INSTALLER SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
• THE APPLIANCE IS NOT INTENDED FOR USE BY CHIL-
DRENOR INFIRM PERSONS WITHOUT SUPERVISION.
• YOUNG CHILDREN SHOULD BE SUPERVISED TO
ENSURE THAT DO NOT PLAY WITH THE APPLIANCE

SAFETY INSTRUCTIONS

1
Precautions When Wiring:
• Do not plug in the unit until all connections (tubing,
drain hose, mounting, etc.) have been made and dou-
ble-checked.
• High voltages are present in this unit and are very dan-
gerous. Please refer to these instructions and diagrams
when wiring. Improper connections or inadequate
grounding can cause accidental injury.
• This unit must be grounded in accordance with local
electrical codes.
• Connect wires and pipes securely and tightly as loose
connections/wiring may cause overheating at connec-
tions and a possible fire hazard.
Precautions When Transporting:
• When transporting the unit, be very careful and get help
as the units are very heavy. Be careful of sharp edges
on the units also.
Precautions When Installing:
• When installing in a ceiling or wall, make sure the
ceiling/wall is strong enough to hold the unit's weight. A
frame may be necessary for added support.
• When installing in a room, make sure the tubes are
well insulated to protect the walls and furniture from
sweating of the tubes.
• When installing in moist or uneven locations, make
sure to use a raised level concrete pad or concrete
blocks to provide a level, solid foundation for the out-
door unit; this prevents water damage and vibration.
• When installing in an area of high winds, make sure
to securely anchor the outdoor unit down with bolts and
a metal frame.
When Connecting Refrigerant Tubing:
• Keep all tubing as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of
the flare and union tubes before connecting them, then
tighten , making sure not to overtighten.
• Check the tubes carefully for leaks before starting the
test run.
When Servicing:
• Make sure the power is off and the unit is unplugged
before opening the unit to troubleshoot or repair electri-
cal parts and wiring.
• Keep your fingers and clothing away from any moving
parts.
• Clean up the sight after you finish, making sure no
metal scraps and wiring are left in the unit.
• The Air conditioner shall be installed in accordance with
the nationed wiring regulation.

Advertisement

Table of Contents
loading

Summary of Contents for Daewoo DSB-182L

  • Page 1: Safety Instructions

    • Use the flare method for connecting tubing. local installer for help. If you require help with service, • Apply refrigerant lubricant to the matching surfaces of contact your certified dealer or Daewoo Electronics for the flare and union tubes before connecting them, then additional instructions.
  • Page 2 ROOM AIR CONDITIONER INSTRUCTION Remark per EMC Directive 89/336/EEC To prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply. 1. The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an low impedance.
  • Page 3: Table Of Contents

    CONTENTS It is recommended that you read Operating instructions fully before operating this unit. Safety Instructions ................................1 Contents ....................................3 OPERATING SECTION Location of Controls................................4 Indoor Unit..................................4 Outdoor Unit .................................4 Indoor unit Display................................5 Remote Controller ................................6 Remote Display................................6 Operation .....................................8 Connecting the AC Cord ..............................8 How to Install Batteries ..............................8 Setting the Unit for Remote Operation.........................8 Celsius to Fahrenheit Conversion Chart........................9...
  • Page 4: Operating Section Location Of Controls

    OPERATING SECTION LOCATION OF CONTROLS INDOOR UNIT Deodorizing Filter Removes bad Electrostatic Filter Emergency/ smells from the air. Removes dust Remote Switch Air In particles from the air. Slide to select the desired position. Sensor Wire Indoor Cover (Only DSB-182LH/LH-R ) Remote Sensor Air Cleaning Filters...
  • Page 5: Indoor Unit Display

    INDOOR UNIT DISPLAY Indoor Unit Display Switch Panel Remote Control Signal Receiver This place is the part to receive the signal if it receives the signal, you can hear the signal “beep. beep”. EMERGENCY REMOTE TIMER QUICK When the remote controller is lost or out- AIR CLEAN of-order, push the emergency button (EMERGENCY) to operate by hand.
  • Page 6: Remote Controller

    REMOTE CONTROLLER DSB-182L DSB-182L-R Display AUTO Displays information pertaining to unit. ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower FAN SPEED Button the desired temperature. Press to select the fan speed (High "...
  • Page 7 REMOTE CONTROLLER DSB-182LH Display AUTO DSB-182LH Displays information pertaining to unit. ON/OFF Button Press to turn the unit on or off. TEMPERATURE Buttons Press to raise or lower FAN SPEED Button the desired temperature. Press to select the fan speed FAN DIR.
  • Page 8: Operation

    OPERATION CONNECTING THE AC CORD The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the indoor unit to AC, follow the procedures below: 1. Insert the attached NOTES: AC plug into a 2- •...
  • Page 9: Celsius To Fahrenheit Conversion Chart

    CELSIUS TO FAHRENHEIT CONVERSION CHART CELSIUS FAHRENHEIT CELSIUS FAHRENHEIT 64.4 78.8 66.2 80.6 82.4 69.8 84.2 71.6 73.4 87.8 75.2 89.6 NOTES: • When operating the remote controller, make sure there are no obstructions between the remote controller and the remote sensor. •...
  • Page 10: To Operate Only Fan

    TO OPERATE ONLY FAN To operate only the fan so the unit will circulate the air, proceed as follows: 1. Press the ON/OFF button on the remote control to 2. Press the MODE button until the Fan indicator turn the unit on; the On LED will light on the indoor appears in the display.
  • Page 11: To Set Unit To Dehumidifier Mode

    TO SET UNIT TO DEHUMIDIFIER MODE Select this mode when there is high humidity. To select, follow the procedures below. 1. Press the ON/OFF button on the remote control to 2.Press the MODE button until the turn the unit on; the On LED will light on the indoor Dehumidifier indicator appears in the dis- unit and “ON”...
  • Page 12: To Set Unit To Quick Mode

    TO SET UNIT TO QUICK MODE To set this unit to cool at the highest power, follow the procedures below: 1. Press the ON/OFF button on the remote control to 2. Press the MODE button until the Quick turn the unit on; the On LED will light on the indoor “...
  • Page 13: To Set The Off Timer Mode

    TO SET OFF TIMER MODE This unit can be set to automatically turn off after a predetermined amount of hours (up to 12) in the order of 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, 7.5, 8, 8.5, 9, 9.5, 10, 11, 12. 1.
  • Page 14: To Set Unit To Heat Mode (Only Lh/Lh-R)

    TO SET UNIT TO HEAT MODE (ONLY DSB-182LH/182LH-R) To set the unit to heat the room to a desired temperature, follow the procedures below: 1. Press the ON/OFF button on the remote control to 2. Press the MODE button until the Heat turn the unit on;...
  • Page 15: Changing/Cleaning The Air Filters

    CHANGING/CLEANING THE AIR FILTERS To change or clean the two black air filters, follow the procedures below: 1. Open the indoor unit’s cover and remove both black 2. Remove the two small filters (Deodorizing and air filters by bending them slightly backward and the Electrostatic) from the indoor unit.
  • Page 16: Care And Maintenance

    CARE AND MAINTENANCE warning • Make sure the AC cord is unplugged and the unit is off before cleaning. • Do not use water on the unit to clean it. This is a shock hazard and the unit can be damaged. •...
  • Page 17: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Before requesting service, please refer to the chart below for possible solutions: SYSPTOMS POSSIBLE CAUSE POSSIBLE SOLUTIONS No power. Power failure. Restore the power Line voltage too low. Contact electrician to install new outlet. Unit is unplugged or not completely Insert plug all the way.
  • Page 18: Specifications

    SPECIFICATIONS MODEL DSB-182L DSB-182L-R DSB-182LH DSB-182LH-R Function Cooling Cooling / Heating Power Supply AC 220-240V, 50Hz 17,500 BTU/h 18,000 BTU/h Cooling Capacity (Heating Mode) 17,500 BTU 18,000 BTU/h (18,500 BTU/h) (18,000 BTU/h) Operating Current (Heating Mode) 9.6A 9.2 A 9.65 A (10.0 A) 9.2 A (9.5 A)
  • Page 19 OWNER'S MANUAL MODEL #: DSB-182L / DSB-182LH DSB-182L-R / DSB-182LH-R SPLIT AIRCONDITIONING SYSTEM...