ICP Induced Combustion Gas Furnace Owner's Information page 20

Induced combustion gas furnace
Table of Contents

Advertisement

Figure 4 - Lowest Temperature
Setting
1t1"1
2. Close the external manual gas valve.
Figure 5 - Close Valve
--h
3. Turn OFF electrical supply to the furnace.
Figure 6 - Turn Off Electrical Supply
A08175
A06188
A92185
4. Remove the outer door by turning knobs clockwise and
lift door upward, then pull door forward.
Figure 7 - Remove Furnace Door
UNLOCK
UNLOCK
5. Turn the control switch on the gas control to the OFF
position and wait 5 minutes.
See Figure 7. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow "B" on furnace label. If you don't smell gas, go to
next step.
Figure 8 - Control Switch to OFF
OR
/
A02266
6. After waiting 5 minutes,
if you still smell gas, STOP!
Follow the safety information on the cover of this manual.
If you do not smell gas, go to the next step.
7. Turn the control switch to ON.
Figure 9 - Control Switch to ON
©
OR
/
A02267
8. Replace the outer door by placing flange inside casing,
push
door
firmly
against
casing
and
turn
knobs
counterclockwise
to tighten.
Figure 10 - Furnace
Door Replaced
9. Turn ON the electrical supply to the furnace.
4
Specifications
subject to change without notice.