ICP C8MPL User's Information Manual
ICP C8MPL User's Information Manual

ICP C8MPL User's Information Manual

Condensing gas furnaces 95% upflow/horizontal, 90+ & 95% four position furnaces, non-condensing gas furnaces & 80+ four position furnaces

Advertisement

Condensing Gas Furnaces
95% Upflow/Horizontal
*9UHX
90+ & 95% Four Position Furnaces
N9MP1, N9MP2, N9MPD,
*9MPD, *9MPT, *9MPV, *9MPX & *9MVX
Non-Condensing
Gas Furnaces
80+ Four Position Furnaces
N8MPN/L, *8MPN/L, *8MPT & *8MPV
*8DNL (Downflow only)
I
FIRE OR EXPLOSION
HAZARD.
I
I
Failure
to
follow
this
warning
I
could
result
in injury,
death
and/or
property
damage.
--Do
not store
or use
gasoline
or
other flammable
vapors
and liquids
in the vicinity
of this or any other
appliance.
-- WHAT TO DO IF YOU SMELL GAS
, Do NOT try to light any appliance.
, Do
NOT
touch
any
electrical
switch;
do NOT use any phone
in
your building.
, Leave the building
immediately
, Immediately
call your gas supplier
from
a neighbor's
phone.
Follow
the gas supplier's
instructions.
, If you
cannot
reach
your
gas
supplier,
call the fire department.
--Installation
and service must be
performed
by a qualified installer,
service agency or the gas supplier.
Installer: Affix these instructions
on or adjacent to the furnace.
Printed in U.S.A.
International
Comfort Products, LLC
Lewisburg, TN 37091 U.S.A.
User: Please read all instructions
in the manual and retain these
instructions for future reference.
441 02 2012 01
June 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C8MPL and is the answer not in the manual?

Questions and answers

Summary of Contents for ICP C8MPL

  • Page 1 Condensing Gas Furnaces 95% Upflow/Horizontal *9UHX 90+ & 95% Four Position Furnaces N9MP1, N9MP2, N9MPD, *9MPD, *9MPT, *9MPV, *9MPX & *9MVX Non-Condensing Gas Furnaces 80+ Four Position Furnaces N8MPN/L, *8MPN/L, *8MPT & *8MPV *8DNL (Downflow only) FIRE OR EXPLOSION HAZARD. Failure follow this...
  • Page 2: Table Of Contents

    User's Information Manual Contents About Your Furnace ....... Danger, Warning and Caution ....Safety Rules ......Operating Your Furnace ....Furnace Maintenance ...... Combustion Air (Your Safety) ....Indoor Humidity (Your Comfort) ....Danger,Warning and Caution Recognize safety information. Product Labeling Signal words are used in combination with colors and/or pictures on This is the safety-alert symbol Z_.
  • Page 3: Safety Rules

    User's Information Manual structure. Air starvation signals are given in the following "Combustion Air (Your Safety)". section of this manual. any of the signals are noticed, perform a combustion air PERSONAL INJURY, DEATH AND/OR PROPERTY check as shown in the following Combustion Air Checks section of this manual or call a qualified service agency.
  • Page 4: Combustionair (Yoursafety)

    User's Information Manual Main Burner Flame: Check for the following: Be aware of these signals; • Stable and blue flames. See Figure 1. Headaches-Nausea-Dizziness • Flames extending directly from burner into heat Excessive humidity-heavily frosted windows or a moist exchanger. "clammy"...
  • Page 5: Indoor Humidity(Yourcomfort)

    User's Information Manual If draft hood spillage is indicated: Circulating Air Blower Check for plugged vent connectors and chimneys. Repair The blower circulates room air through the furnace, air ducts, and stoppage and test again. into the rooms of the structure. The blower can be set at the thermo- If you have a fireplace, open a window or door near the fire- stat for automatic or manual operation.
  • Page 6 User's Information Manual Component Locations for Condensing 90+ Furnaces - inches(mi,,imeters) iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii Furnace Vent Pipe (Vent Pipe Connections through Side Panel on Some Models) . Air Intake Pipe " I,-- _/'i -_fz_ _.___<.____..( Required only for Direct-Vent Furnaces) Manual GasShutoff Valve ..
  • Page 7: Operatingyour Furnace

    User's Information Manual Set the room thermostat slightly above room temperature. This will Turning Off The Furnace automatically signal the furnace to start. The inducer motor will Set the thermostat to the lowest temperature setting or set System start, and the hot surface igniter will have an orange glow. After Select Switch to OFF, if so equipped.
  • Page 8: Furnace Maintenance

    User's Information Manual bustion blower. Insert a funnel intothe hose and pour four (4) ounces of sanitary type (RV) antifreeze into the condensate trap. Reconnect the _/2" (12.7mm) I.D. rubber hose to the stub on the vent drain fitting. Secure with the hose clamp. Honeywell Gas Control Valve...
  • Page 9 User's Information Manual If a cleanable (high-velocity) filter(s) is to be replaced with a dispos- Filter R ac k 0 utsid e Furn ace able (low-velocity) fitter(s), the airflow area of the filter(s) must be doubled (i.e., a second filter of the same size must be installed so iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii that only half of the air goes through each filter).
  • Page 10 User's Information Manual Turn OFF power to furnace. 1. Turn OFF electric power to furnace. Remove compartment door. 2. Remove the end cap from the filter rack. Reach up above right side of blower, and lift dirty filters out of 3.

Table of Contents