Compatible Devices; Important Installation Highlights (Installer Please Read) - Honeywell VISTA 15P - Ademco 6 Zone Control Panel Installation And Operation Manual

Ademco vista series
Hide thumbs Also See for VISTA 15P - Ademco 6 Zone Control Panel:
Table of Contents

Advertisement

Installation and Setup Guide

Compatible Devices

Device
Addressable Keypads
Touch Screen (AUI)
Devices
4219, 4229 Zone
Expander Modules
5800 Series Wireless
Output relays and/or
Powerline Carrier
Devices (X-10 type)
On-Board Triggers
Output functions
4286 Phone Module
Audio Alarm
Verification
Alarm output
Auxiliary Power Output
Backup Battery
Long Range Radio
(Communication Device)
AC Power Supply
NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canada.

Important Installation Highlights (Installer Please Read)

• This system uses addressable keypads and Zone Expander Modules (see Table of Addresses in
Section 2. Mounting and Wiring – Wiring the Keypads and Other Addressable Devices).
• Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from
previous controls) and programmed in data fields *190-*196.
• Zone Expander Modules must be set for specific addresses (07-11), based on the zone numbers used.
• 4204 Relay Modules must be set for specific addresses (12-15).
• This control will not power-up unless AC power is connected (will not power-up on battery alone).
However, once the system is powered up, it will operate on battery power in the event of AC loss.
• Relays have two programming menu modes: Use *79 Menu mode to map module addresses and
device (output) numbers. Use *80 Menu mode to define the output functions.
• This system supports programmable function keys. Use *57 Menu mode to define the function
keys.
1-2
VISTA-20P
VISTA-15P
8
8
4
2
Up to 5 for
Up to 2 for
up to 40
up to 16
exp. zones
exp. zones
Up to 40 RF
Up to 26 RF
zones
zones
Up to 16
Up to 8
2
2
Up to 48
Up to 24
Partition 1
yes
only
Using AAV
Using AAV
module
module
12VDC, 2
12VDC, 2
AMP output
AMP output
See note.
See note
See note.
See note.
See note.
See note.
See note.
See note.
Notes
6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V
Fixed-Word Display Voice Keypad, 6160V Alpha
Display Voice Keypad, 6150RF Keypad/Transceiver
Touch Screen (AUI) devices are in addition to the 8
addressable keypads. E.g., Symphony, 6270
Zone numbers are predefined according to the device
addresses used. See Expander Module Addresses table
in Wiring section and set addresses accordingly.
Uses 5881/5883 Series Receivers/Transceivers.
Use any combination of 4204, 4229 and or Powerline
Carrier Devices.
Map output devices via *79 Menu mode.
Can be used to reset 4-wire smoke detectors.
Program output functions via *80 Menu mode.
Provides access to the system via on premises or off-
premises phones for arming, disarming, etc., plus
control of relay outputs and Powerline Carrier devices.
Use ADEMCO UVS or Eagle Model 1250 in
conjunction with an output trigger to permit voice
dialog between an operator at the central station and
a person at the premises. Alternatively, the AVS
system can be used to provide AAV via phone line or
AlarmNet IP/GSM (using a GSMV module).
Can drive the compatible sounders; steady output for
burglary/panic, or temporal pulse (3 pulses – pause –
3 pulses – pause – 3 pulses. . .) for fire. Uses current
limiting circuitry for protection.
12VDC, 600 mA maximum; uses circuit protection.
Rechargeable (sealed lead-acid type) 12VDC, 4AH
minimum.
Primary telephone number messages can be reported
via ECP connection to various communication devices
(check compatibility/availability of specific models)
Plug-in 120VAC transformer, 1321 (1321CN in
Canada) or, if using Powerline Carrier devices,
1361X10 Transformer Module