Enabling The Disk Write Cache (Dwc) - Asus P9D-I Manual

P9d-i manual
Table of Contents

Advertisement

5.2.8
Enabling the Disk Write Cache (DWC)
You may manually enable the RAID controller's Disk Write Cache option after creating a RAID
set to improve the data transmission performance.
When you enable DWC, you may lose data when a power interruption occurs while transmitting
or exchanging data among the drives.
The WriteCache function is recommended for RAID 1 and RAID 10 sets. You have to
manually configure the Adapter and the Virtual Drive of the RAID set you created.
To enable DWC:
From the Management Menu, select Objects > Adapter. Select an existing adapter then
1.
press <Enter> to display the adapter properties.
Select Disk WC then press <Enter>.
2.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Select On from the Change DWC and press <Enter> to turn on the option.
3.
Go to Management Menu, select Objects > Virtual Drive. Select an existing Virtual
4.
Drive and press <Enter>.
5-32
LSI Software RAID Configuration Utility Ver C.05 Oct 26, 2011
BIOS Version
Objects
Adapter
Virtual Drive
Physical Drive
Disk Write Cache - Off(Write Through or On(Write Back)
A.11.02090932R
Adapter 0
Rebuild Rate
= 30
Chk Const Rate = 30
FGI Rate
= 30
BGI Rate
= 30
Disk WC
= Off
Read Ahead
= On
Bios State
= Enable
Cont On Error
= Yes
Fast Init
= Enable
Auto Rebuild
= On
Auto Resume
= Enable
Disk Coercion
= 1GB
Factory Default
Chapter 5: RAID configuration