Vwho 18"H. Outdoor Wall Hoods 36", 48; Dimensions & Specifications - Viking VBCV36381 Installation Instructions Manual

Professional & outdoor hoods
Hide thumbs Also See for VBCV36381:
Table of Contents

Advertisement

Dimensions & Specifications
(VWHO 18"H. Outdoor Wall Hoods 36", 48", & 60")
NOTE: Optional duct cover sold separately.
VWHO 18"H. Outdoor Wall Hoods
Description
36"
Duct cover width
35-7/8" (91.1 cm)
Duct cover depth
Duct cover height
Number of lights
2
Number of filters
2
Interior ventilator kits
VINV1200*
Exterior ventilator kits
DEV1200*/1500**
In-line ventilator kits
DIL1200
Interior duct size
Exterior duct size
Interior—Maximum amps
9.0
Exterior—Maximum amps
6.1/6.8
In-Line—Maximum amps
7.9
* A 1,200 CFM interior- or exterior-power ventilator should be used with all T-Series models and when i ndoor models are
installed over range/rangetop with gas char-grill. Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18"H. hoods.
12
48"
60"
47-7/8" (121.6 cm)
59-7/8" (152.1 cm)
12" (30.5 cm)
12" (30.5 cm)
3
4
3
4
VINV1200*
VINV1200*
DEV1200*/1500**
DEV1200*/1500**
DIL1200
DIL1200
10" (25.4 cm)
10" (25.4 cm)
11.4
11.8
8.4/9.1
8.8/9.5
10.2
10.6
Clearance Dimensions
(VWHO 18"H. Outdoor Wall Hoods)
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from
the elements as much as possible.
The bottom of the hood should be 30" (76.2 cm) to 36" (91.4 cm) above the grill surface. The hood
should be installed 4-1/2" (11.4 cm) plus the distance between the back trim and surface from the back
wall. (Note: There is a 3" minimum clearance from the back trim to non-combustible surfaces, and a 24"
minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible
material used for this purpose must be covered with locally-supplied stainless steel. Viking also
recommends using a backsplash.