Fujitsu 50FH5037E-02 Oem Manual page 58

Image scanner
Table of Contents

Advertisement

(a)
Control register #0
X©00π is set when the power is turned on or when a CLEAR command is issued for
initialization.
MSB
7
6
5
4
3
0
*1 When the start of reading is specified from the operator panel, the Ready lamp
lights at reception of a START command.
6 $ 8
LSB
2
1
0
Scanning resolution
0¥¥¥ : Set from the operator panel
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
Flatbed/ADF
0¥ :
1 0 :
1 1 :
Specified start of reading
0
1
50FH5037E>02
400 dpi
300 dpi
240 dpi
200 dpi
Not defined
Set from the operator panel
Flatbed operation
ADF operation
:
Operator panel (*1)
:
Host computer

Advertisement

Table of Contents
loading

This manual is also suitable for:

M3097e

Table of Contents