Error Code
Message Information
Action
SEL0006
Message
Details
Action
SEL0008
Message
Details
Action
SEL0012
Message
Details
Action
SEL1204
Message
Details
Action
TMP0118
Message
Details
Action
TMP0119
Message
Details
Action
Close the chassis and verify hardware inventory. Check system logs.
All event logging is disabled.
This message is displayed when all event logging has been disabled
by the user.
If unintended, re-enable logging.
Log is full.
When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.
Backup and clear log.
Could not create or initialize the system event log.
If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.
An unknown system hardware failure detected.
If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.
Re-configure system to the minimum supported configuration. If
issues persists, contact support.
The system inlet temperature is less than the lower warning
threshold.
Ambient air temperature is too cool.
Check the system operating environment.
The system inlet temperature is less than the lower critical threshold.
Ambient air temperature is too cool.
Check the system operating environment.