Error Code
Message Information
Details
Action
PSU0034
Message
Details
Action
PSU0035
Message
Action
PSU0036
Message
Details
Action
PSU0037
Message
Action
PSU0076
Message
Details
Action
PSU1201
Message
118
System performance may be degraded.
Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
An under voltage fault detected on power supply <
This failure may be the result of an electrical issue with cables or
subsystem components in the system.
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see
An over voltage fault detected on power supply <
Check input power or reinstall the power supply. If the issue persists,
see
Getting
Help.
An over current fault detected on power supply <
This failure may be the result of an electrical issue with cables or
subsystem components in the system.
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see
Fan failure detected on power supply <
Check for fan blockage. If the problem persists, see
A power supply wattage mismatch is detected; power supply
number > is rated for < value > watts.
<
Power supplies should be of the same input type and power rating.
Install matched power supplies and review this manual for proper
configuration.
Power supply redundancy is lost.
number >.
Getting
Help.
number >.
number >.