Step 3 – Create a Web-Login Page
From the RADIUS Services Web Logins page select the Create New Web Login page option
at the bottom of the page. From the RADIUS Web Login page enter a name and description of
the Web Login page you are creating.
Optionally you can set a preferred page name that will make up the Web Login URL. In this
example we have chosen to use procurve_login as the name and the resulting URL in this lab
environment will be:
http://10.0.20.60/procurve_login.php
The Submit URL is made up of the IP Address of the HP ProCurve MSM, the port number used
for HTTP authentication and a URL suffix defined by HP ProCurve to be:
/goform/HtmlLoginRequest
Ensure the Submit Method is set to POST.
9
CONFIDENTIAL
Need help?
Do you have a question about the PowerConnect W Clearpass 100 Software and is the answer not in the manual?