Brocade Communications Systems PowerConnect B-FCXs Release Note page 50

Ironware software release r07.2.00a for brocade fesx, fsx, sx, fcx, fgs, fgs- stk, fls, fls-stk, and fws switches
Table of Contents

Advertisement

Defect ID: DEFECT000319621
Summary: On SX 800/1600 with zero port management module and only SX-48GC line modules,
multicast over GRE tunnels is not functional.
Symptom: On SX 800/1600 with zero port management module and only SX-48GC line modules,
multicast over GRE tunnels is not functional.
Workaround: This issue does not happen if the chassis has a non-zero port management module or at
least one IPV6 or IPV4 line module.
Feature: SX L2/L3 Multicast Features
Reported In Release: FI 07.2.00
Defect ID: DEFECT000266855
Summary: When reloading a unit, ports on the unit keep "up" to the neighbors. If it is a cross-module
trunk, connectivity can be affected.
Symptom: The ip interface of the trunk is UP, the OSPF neighbor adjacency may timeout.
Workaround: Do not configure a "dead-interval" less than the default 40 seconds, so that the Reload will
be completed prior to the expiration of "dead-interval". Or even configure it larger than
the default such as 60 seconds.
Feature: FCX Layer3 Control Protocols
Reported In Release: FI 06.0.00
Defect ID: DEFECT000269117
Summary: lldpLocManAddrTable and lldpRemManAddrTable do not display correct IPv4 and IPv6
address.
Symptom: lldpLocManAddrTable and lldpRemManAddrTable do not display correct IPv4 and IPv6
address.
Feature: FCX Network Management
Reported In Release: FI 07.0.00
Defect ID: DEFECT000275416
Summary: Web Management does not force stack priority become after first reload. A second reload is
required.
Symptom: A second reload is required to change stack priority via web management
Feature: FCX Network Management
Reported In Release: FI 07.0.01
IronWare Software Release 07.2.00a for Brocade FastIron switches
Release Notes v 1.0
Technical Severity:
Function:
PIM Sparse
Technical Severity:
Function:
OSPFV2 - IPV4
Technical Severity:
Function:
SNMP V4/V6
Probability:
Medium
Technical Severity:
Function:
Web Management
Probability:
Medium
High
Medium
Medium
Medium
Page 50 of 55