Brocade Communications Systems PowerConnect B-FCXs Release Note page 42

Ironware software release r07.2.00a for brocade fesx, fsx, sx, fcx, fgs, fgs- stk, fls, fls-stk, and fws switches
Table of Contents

Advertisement

Summary: In the base Layer3 and Layer3 software, when sflow is enabled, packets with priority 1 that
are destined to the CPU are dropped.
Symptom: In the base Layer3 and Layer3 software, when sflow is enabled, packets with priority 1 that
are destined to the CPU are dropped.
Probability: Medium
Feature: SX L2 Forwarding
Reported In Release: FI 07.0.01
Defect ID: DEFECT000288606
Summary: With MSTP configured, adding and removing VLANs from the switch may cause brief packet
loss.
Symptom: There may be brief packet loss when adding a port to a VLAN running MSTP.
Probability: Medium
Feature: SX L2 Control
Reported In Release: FI 04.1.00
Defect ID: DEFECT000289865
Summary: Wrong Fan Failed message is displayed for FWS648G-non POE.
Symptom: Fan error messages seen.
Probability: High
Feature: FCX Platform Specific features
Reported In Release: FI 07.0.01
Defect ID: DEFECT000297038
Summary: Some packets which need to be fragmented are getting delayed, causing packet loss.
Symptom: Some packets which need to be fragmented are getting delayed, causing packet loss.
Probability: Medium
Feature: SX Layer 3 Forwarding - IPV4 and IPV6
Reported In Release: FI 05.1.00
IronWare Software Release 07.2.00a for Brocade FastIron switches
Release Notes v 1.0
Function: VLAN Manager
Service Request ID: 241991
Technical Severity: Medium
Function: Spanning Tree Protocols
Service Request ID: 237710
Technical Severity: Medium
Function: Chassis/fan/power
supplies/temperature sensors
Service Request ID: 246043
Technical Severity: Medium
Function: IP MTU & Fragmentation
Service Request ID: 245120
Page 42 of 55

Advertisement