Samsung VC240 Reference Manual page 37

Reference guide
Hide thumbs Also See for VC240:
Table of Contents

Advertisement

Table 1-26
Ports Supported by SCOPIA MCU
Port
Protocol/Use
3336
XML (TCP)
3337
XML (TCP)
5060
SIP (TCP/UDP) SIP signaling
(configurable)
6000-6999
RTP/RTCP
(configurable)
(UDP)
10000-11000
RTP/RTCP
(configurable)
(UDP)
In addition to the ports listed in
levels enabling and disabling Telnet, FTP , SNMP and ICMP (ping) services, as shown in
Table 1-27
Security Mode
Standard
High
Maximum
Media Video Processor for SCOPIA MCU
Table 1-28
Table 1-28
MVP-supported Ports
Port
Protocol/Use
21
FTP (TCP)
23
Telnet (TCP)
161 (for
SNMP (UDP)
future use)
2946
MEGACO (TCP)
RADVISION | RADVISION Port Security Reference Guide
Functionality
MCU version 3 XML API Both
MCU version 3
Cascading XML API
RTP/RTCP audio
RTP media
Table
Security Modes
SCOPIA MCU
Telnet
FTP
Active
Active
Inactive
Inactive
Inactive
Inactive
lists the ports supported by the MVP .
Functionality
Software upgrade and
video stream recording
MVP online log
Configuration and
status
Control protocol
between MCU and MVP
Direction Result of Blocking
Port on Firewall
Cannot use MCU
Conference Control
web user interface.
Cannot use version 3
XML API to control MCU
Both
Cannot cascade
between two MCUs
Both
Cannot connect SIP
calls
Both
Cannot
transmit/receive audio
stream
Both
Cannot
transmit/receive
media stream
1-27, RADVISION MCUs offer configurable security access
SNMP
ICMP (ping)
Active
Active
Active
Active
Inactive
Inactive
Direction
Result of Blocking
Port on Firewall
Both
Cannot upgrade
version
Both
Cannot view logs
Both
Cannot configure
or check the status
of the MCU via
SNMP
Both
MVP cannot
connect to MCU
Description
Conference Control web
client terminal, iVIEW
Management Suite or
third-party controlling
applications
Other MCUs
Any SIP entities
Any RTP/RTCP media
enabled entity
Any H.323 or SIP media
enabled entity
Table
1-27.
Description
Upgrade Utility
Telnet client
iVIEW Network Manager,
iVIEW Management Suite
or any other SNMP
manager station
MEGACO (H.248) Protocol