Address Translation; Default Parameters - Fujitsu MPF3XXXAT Product Manual

Fujitsu computer drive user manual
Hide thumbs Also See for MPF3XXXAT:
Table of Contents

Advertisement

6.2

Address Translation

When the IDD receives any command which involves access to the disk medium, the IDD
always implements the address translation from the logical address (a host-specified address)
to the physical address (logical to physical address translation).
Following subsections explains the CHS translation mode.
6.2.1

Default parameters

In the logical to physical address translation, the logical cylinder, head, and sector addresses
are translated to the physical cylinder, head, and sector addresses based on the number of
heads and the number of sectors per track which are specified with an INITIALIZE DEVICE
PARAMETERS command. This is called as the current translation mode.
If the number of heads and the number of sectors are not specified with an INITIALIZE DEVICE
PARAMETERS command, the default values listed in Table 6.1 are used. This is called as the
default translation mode. The parameters in Table 6.1 are called BIOS specification.
Number of cylinders
Parameters
Number of head
(logical)
Number of sectors/track
Formatted capacity (MB)
As long as the formatted capacity of the IDD does not exceed the value shown on Table 6.1,
the host can freely specify the number of cylinders, heads, and sectors per track.
Generally, the device recognizes the number of heads and sectors per track with the
INITIALIZE DEVICE PARAMETER command. However, it cannot recognizes the number
of cylinders. In other words, there is no way for the device to recognize a host access area on
logical cylinders. Thus the host should manage cylinder access to the device.
The host can specify a logical address freely within an area where an address can be specified
(within the specified number of cylinders, heads, and sectors per track) in the current
translation mode.
The host can read an addressable parameter information from the device by the IDENTIFY
DEVICE command (Words 54 to 56).
6 - 6
Table 6.1
Default parameters
MPF3102AT
10,248.1
C141-E099-01EN
MPF3153AT
MPF3204AT
16,383
16
63
15,371.9
20,496.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpf3102atMpf3153atMpf3204at

Table of Contents