2LY/2LZ
(3) Detaching and refitting the operation panel PWB
Procedure
1. Remove the top cover (See page 1-5-3).
2. Remove two screws and then remove the
panel cover.
3. Remove the operation panel PWB.
4. Remove the connector.
5. Check or replace the operation panel PWB
and refit all the removed parts.
Be sure to fit the GO and Cancel keys in the
appropriate position.
1-5-24
Operation panel PWB
Top cover
GO key (Green)
Cancel key (Amber )
Figure 1-5-33
Screw
Panel cover
Screw
Connector
Cancel key
( Amber )
GO key (Green)