1-5-9
Others
(1) Detaching and refitting the main motor
Procedure
1. Remove the right cover (See page 1-5-4).
2. Remove the connector.
3. Remove the M3 screw and two M4 screws.
4. Remove the main motor.
5. Check or replace the main motor and refit all
the removed parts.
Figure 1-5-40
Main motor
Figure 1-5-41
2LY/2LZ
Connector
M3 Screw
M4 screws