Dell External M620 t Owner's Manual page 99

Owners manual
Table of Contents

Advertisement

Error Code
Message Information
Action
MEM1214
Message
Details
Action
MEM7002
Message
LCD Message
Details
Action
MEM8000
Message
LCD Message
Details
Action
OSE0000
Message
Details
Action
OSE0001
Message
Details
Action
OSE0004
Message
Details
Review system logs for memory exceptions. reinstall memory at
location >
location <
Memory redundancy is degraded.
The memory may not be seated correctly, misconfigured, or has
failed.
Check the memory configuration. Re-seat the memory modules. If the
issue persists, see
Getting
A hardware mismatch detected for memory riser.
Memory riser mismatch detected. Check memory riser.
Memory riser is installed incorrectly, or failed.
Check that the memory riser is installed correctly. If the issue
persists, see
Getting
Help.
Correctable memory error logging disabled for a memory device at
location >.
location <
location >. Re-seat memory.
SBE log disabled on <
Errors are being corrected but no longer logged.
Review system logs for memory exceptions. reinstall memory at
location >.
location <
A critical stop occurred during OS load.
The system halted due to an exception during operating system load
or operating system initialization.
Review operating system logs and system video for additional
information.
A runtime critical stop occurred.
The system halted due to an exception while the operating system
was running. This is a kernel panic or bug check event.
Review operating system logs and system video for additional
information.
A soft shut-down initiated by platform event filter.
A separate exception or status condition shutdown the operating
system. (IPMI sensor type 20h - offset 04h).