Dell External M620 t Owner's Manual page 83

Owners manual
Table of Contents

Advertisement

Error Code
Message Information
LCD Message
Details
Action
CPU0002
Message
Action
CPU0003
Message
Action
CPU0004
Message
Action
CPU0005
Message
LCD Message
Details
Action
CPU0006
Message
Details
number > has a thermal trip. Check CPU heat sink.
CPU <
The processor temperature increased beyond the operational range.
Review logs for fan failures, replace failed fans. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat-sink.
number > has failed the built-in self-test (BIST).
CPU <
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see
number > is stuck in POST.
CPU <
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Reduce system configuration to minimum memory and remove
all PCI devices. If system completes POST, update system BIOS.
reinstall memory and PCI one component at a time to meet the
original configuration.
3. If the issue persists, see
number > failed to initialize.
CPU <
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see
number > configuration is unsupported.
CPU <
number > configuration is unsupported. Check CPU or BIOS
CPU <
revision.
System is unable to boot or may run in a degraded state.
Review the technical specifcations for supported processor types.
Unrecoverable CPU complex error detected on CPU <
System is unable to boot or may run in a degraded state.
Getting
Help.
Getting
Help.
Getting
Help.
number >.
83