Standard Cable Pinouts - Honeywell MK7580-30B41-00 - Metrologic MS7580 Genesis User Manual

Presentation area imager
Table of Contents

Advertisement

Standard Cable Pinouts

RS232, 12V VLink Cable
5S-5S000-3
Pin
1
Shield Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4
No Connect
5
Power/Signal Ground
6
Reserved
7
CTS Input
8
RTS Output
9
+12VDC
MX-RS485-5S006-3
Pin
1
Signal/Power Ground
2
IBM A+
3
IBM B-
4
+12VDC
5S-5S213-3 or 5S-5S006-N-3
Pin
Type A
Type A
Locking
Non-Locking
Plus-Power
1
1
2
2
3
3
4
4
5
6
7-8
‡ See page 47 for pinout information specific to the MS7580-124-EAS Genesis model.
50
Function
RS485
Function
USB
Function
PC +5V/V_USB
D-
D+
Ground
Ground
+12VDC
No Connect
(Host End)
9-Pin Female, D-Type
SDL A Key Connector
5S-5S235-N-3
USB Type A
Non-Locking
5S-5S213-3
USB Type A
Locking Plus-Power

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms7580 genesisGenesis 7580

Table of Contents