Mechanical
Height (H):
Width (W):
Depth (D):
Termination:
Electrical
Input Voltage:
Current:
DC Transformer:
For regulatory compliance information see pages 55–58
Environmental
Temperature:
Humidity:
Light Levels:
Contaminants:
Ventilation:
34
150 mm (5.91")
83 mm (3.27")
80 mm (3.15")
340 g ± 15 g
Weight:
(12 oz. ± 5 oz.)
10 pin modular RJ45
Power:
Operating
Operation
Peak Values of at least 1 ms in width.
Class 2; 12VDC @ 1.25 A
Operating = 0°C to 40° (32° to 104°F)
Storage = -40°C to 60°C (-40°F to 140°F)
0% to 95% Relative Humidity, Non-Condensing
Up to 100,000 Lux
Shock:
Designed to withstand 1.5 m (5 ft.) drops
Sealed to resist airborne particulate contaminants
None required
+12 Volt
Adapter Value
12VDC ± 0.25V
Peak
2.0 W (Typical)
1.7 W (Typical)
Idle
1.3 W (Typical)
Peak
167 mA (Typical)
142 mA (Typical)
Idle
109 mA (Typical)
+5 Volt
USB Power Value
5VDC ± 0.25V
1.6 W (Typical)
1.4 W (Typical)
1.0 W (Typical)
320 mA (Typical)
280 mA (Typical)
200 mA (Typical)