Dell PowerEdge VRTX Owner's Manual page 105

Poweredge m620 systems owner's manual
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Error Code
Message Information
Details
Action
PCI3004
Message
Details
Action
PCI3006
Message
Details
Action
PCI3008
Message
Details
Action
PCI3010
Message
Details
Action
PCI3012
Message
Details
Action
PCI3014
Message
Details
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and
does not support FlexAddress.
Update BIOS, BMC/iDRAC, LOM, and PCIe mezzanine card firmware.
If the issue persists, see
Getting
Device option ROM on PCIe mezzanine card <
support Link Tuning or FlexAddress.
Either the BIOS, BMC/iDRAC, or PCIe mezzanine card firmware is out
of date and does not support FlexAddress.
Update BIOS, BMC/iDRAC, and PCIe mezzanine card firmware. If the
issue persists, see
Getting
Failed to get Link Tuning or FlexAddress data from iDRAC.
Either the BIOS or BMC/iDRAC firmware is out of date and does not
support FlexAddress.
Update BIOS, and BMC/iDRAC firmware. If the issue persists, see
Getting
Help.
A non-fatal PCIe error detected on a component at bus
bus >device< device >function < func >.
<
System performance may be degraded.
Cycle input power, update component drivers, remove and reinstall
the device at the next service window.
A non-fatal IO error detected on a component at bus
bus >device< device >function < func >.
<
System performance may be degraded.
Cycle input power, update component drivers, remove and reinstall
the device at the next service window.
The QuickPath Interconnect (QPI) width degraded.
System performance may be degraded. The bus is not operating at
maximum speed or width.
Reset the system, if the problem persists reinstall processors.
A non-fatal PCIe error detected on a component at slot <
System performance may be degraded.
Help.
number > failed to
Help.
number >.
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge m620