Hold the cooling shroud at both ends near the server module chassis and lift it up and away from the server
module.
Figure 8. Installing and Removing a Cooling Shroud
1. pins under the cooling shroud (2)
2. cooling shroud
3. tabs (4)

Installing The Cooling Shroud

CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1.
Position the tabs below the shroud to align with the holes on the heat sink installed on processor socket CPU1.
2.
Lower the cooling shroud into the system until the tabs on the sides of the shroud engage with the slots on the
server module chassis and the pins under the shroud engage with the holes on the heat sink.
3.
Close the server module.
4.
Install the server module in the enclosure.

System Memory

Your system supports DDR3 unbuffered ECC DIMMs (UDIMM ECC) and registered DIMMs (RDIMMs). It supports DDR3
and DDR3L voltage specifications.
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.
30
4. holes on the heat sink (2)
5. slots on the chassis (4)