Accessing Cx4 Ports; Required Cx4 Cable Housing Clearances - Dell Force10 S2410-01-10GE-24P Quick Start Manual

Dell force10 s2410 system quick start guide
Hide thumbs Also See for Force10 S2410-01-10GE-24P:
Table of Contents

Advertisement

Accessing CX4 Ports

CX4 10G copper ports are pre-installed in the S2410CP. Using a CX4 port
requires only the insertion, into the port, of the appropriate CX4 cable with the
correct CX4 cable connector. Using a cable with a bail latch-type connector is
simple: You push the connector into the port. To remove it, simply pull back on
the bail latch. The S2410CP provides up to 1W per port for either active copper
cables or optical-to-electrical converters.
The qualified 15 meter cable is an active cable and requires that the
NOTE:
end labeled "Active" be connected to the S2410CP in order to operate
correctly.
S2410 CX4 ports, because they are tightly packed, only accept cables with a
connector that has a low-profile pull-tab and low-profile cable housing. Using
any cable that is not approved by Dell Force10 might cause interface errors
and/or have issues with mechanical fit. CX4 cables are not included with the
S2410, but Dell Force10 has certified cables to use with the S2410. For a list of
approved cables, see the S2410 data sheet:
http://www.force10networks.com/products/s2410.asp
CAUTION: Use of unqualified cables can result in interface errors, and Dell
Force10 will not support applications using non-qualified cabling.
NOTE: The S2410 CX4 ports auto-sense the length of the attached cable, so their
pre-emphasis does not need to be set manually.

Required CX4 Cable Housing Clearances

The maximum back shell dimensions of an acceptable CX4 connector are
shown below. Use of a CX4 connector that exceeds those dimensions can cause
damage to the S2410CP connectors and possible failure of the interface.
Installing the Hardware
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Force10 s2410

Table of Contents