Setting Items
Setting details (Items in bold are factory default)
08 Volume Input
Fixed (0dB): Fixed at 0dB.
Sets the analog recording
Variable: Mute can be adjusted from -60 – 0 – 10dBu in 0.1dB increments.
input level.
09 Ref (XLR/RCA)
+24dBu/+10dBV: XLR=+24dBu / RCA=+10dBV
Sets
the
input/output
+20dBu/+6dBV: XLR=+20dBu / RCA=+6dBV
standard level.
+18dBu/+4dBV: XLR=+18dBu / RCA=+4dBV
10 Input Trim Lch
+2.0dB – 0dB – -2.0dB
Adjusts the analog input for
the left channel in 0.1dB
increments.
When adjusting it, the sound is output to the output terminal.
11 Input Trim Rch
+2.0dB – 0dB – -2.0dB
Adjusts the analog input for
the right channel in 0.1dB
increments.
When adjusting it, the sound is output to the output terminal.
12 Output Trim Lch
+2.0dB – 0dB – -2.0dB
Adjusts the analog output
for the left channel in 0.1dB
increments.
13 Output Trim Rch
+2.0dB – 0dB – -2.0dB
Adjusts the analog output for
the right channel in 0.1dB
increments.
14 Time Form
12h: Switches to the 12-hour display (AM/PM).
Sets the type of the current
24h: Switches to the 24-hour display.
time display.
15 Date Form
MDY: Displays the date in Month/Day/Year order.
Sets the display order of the
DMY: Displays the date in Day/Month/Year order.
date.
YMD: Displays the date in Year/Month/Day order.
Setting Items
16 Display Contrast
1 – 5 : 1 is the darkest, 5 is the brightest.
Sets the contrast of the
display.
z1
17 Language
Eng: Displays the file names and folder names in English.
Selects the display language
Jpn: Displays the file names and folder names in Japanese.
for the file names and folder
names.
18 Serial Bit Rate
9600: 9600 bps
Sets the serial
38400: 38400 bps
communication bitrate for
RS-232C.
z1
19 Machine Name
DN-500R
Displays the name of the
recorder (maximum 12
characters).
20 Daylight Saving
Off: Daylight saving time is not applied.
Sets daylight saving time.
On: Daylight saving time is applied. Set the start and end date of daylight
saving time and the offset time of up to six hours in 15-minute
increments.
21 Admin Passwd
****: Set the password between 6 to 12 characters.
Sets the Admin Password
for when "System Setting"
is used.
For details on how to input the password, see "Renaming presets"
(vpage 21).
22 Auto Reboot
Off: Does not automatically reboot.
On: Reboots automatically if the main processor freezes.
23 Default
Resets all of the system settings to the defaults.
z1 The DN-500R will automatically reboot (power off and then back on) to enable the settings.
22
Setting details (Items in bold are factory default)
Setting defaults