5-6 Procedures after Completion of Installation
Correct the environment setting using the vi command, etc., referring to the following.
For details of the settings, refer to the online help of snmpd.
# # # #
# Third, create a view for us to let the group have rights to:
# name incl/excl subtree mask(optional)
view all included .1 80
# # # #
# Finally, great the group read-only access to the systemview view.
# group context sec.model sec.level prefix read write notif
access notConfigGroup "" any noauth exact all all none
3. Start setting of portmap
Configure this setting by running esminst.sh. Set portmap to start automatically.
# /sbin/chkconfig --level 345 portmap on
4. Setting firewall
When monitoring from the NEC ESMPRO Manager, use the following port.
If you set the firewall on your environment, set the access permission to the following port.
snmp 161/udp
snmp-trap 162/udp
5. Setting SELinux
NEC ESMPRO Agent uses snmpd.
When a SELinux function is effective, run the following command and remove a limit of snmpd.
# setsebool -P snmpd_disable_trans 1
# /etc/init.d/ft-snmpd restart
Please confirm the setting situation of the SELinux function by carrying out a sestatus command.
"SELinux status:" When is displayed with "enabled", a SELinux function becomes effective.
# sestatus -v