Updating BMC Firmware
4. Obtain the latest BMC image for the Express5800/ftServer
and copy it to the ftServer tmp folder.
N O T E
All ftServers running a supported Linux distribution and
Express5800/ftServer system software for the Linux
Operating System (Express Builder) use the same BMC firmware.
5. Type the following commands to update the BMC firmware on each I/O element:
# /opt/ft/bin/ftsmaint burnProm
path and filename for the BMC firmware
Updated firmware on the device at path 10/120.
# /opt/ft/bin/ftsmaint burnPROM
path and filename for the BMC firmware
Updated firmware on the device at path 11/120.
6. Type the following commands to verify that your BMC firmware is duplexed (be
sure that the opstate is DUPLEX):
# /opt/ft/bin/ftsmaint ls 10/120
# /opt/ft/bin/ftsmaint ls 11/120
7. Type the following commands to verify that the I/O elements are duplexed (be sure
that the opstate is DUPLEX):
# /opt/ft/bin/ftsmaint ls 10
# /opt/ft/bin/ftsmaint ls 11
3-6