Lenovo ThinkServer 1043 Installation And User Manual page 81

Lenovo server installation and user guide
Hide thumbs Also See for ThinkServer 1043:
Table of Contents

Advertisement

Table 17. Submenus under the Mass Storage Controller Configuration
Item
SATA Configuration
Configure SATA as
Notes:
1. The settings in [ ] are the default settings in the Setup Utility program.
2. The SATA Configuration item might not apply because your server came with an integrated SAS controller.
Table 18. Submenus under the SuperIO Configuration
Item
Serial Port1 Address
Serial Port2 Address
Note: The settings in [ ] are the default settings in the Setup Utility program.
Table 19. Submenus under the USB Configuration
Item
Legacy USB Support
USB 2.0 Controller Mode
Hotplug USB FDD Support
Note: The settings in [ ] are the default settings in the Setup Utility program.
For external USB devices, the USB Mass Storage Device Configuration submenu is as below:
Emulation Type
Table 20. Submenus under the Hardware Health Configuration
Item
Items and options with BMC configuration:
Auto Fan Control
PWM Minimal Duty Cycle
Sensor Data Register Monitoring
Items and options without BMC configuration:
Option
Disabled / [Enabled]
[IDE] / RAID
Option
Disabled / [3F8/IRQ4] / 3E8/IRQ4 /
2E8/IRQ3
Disabled / [2F8/IRQ3] / 3E8/IRQ4 /
2E8/IRQ3
Option
Disabled / [Enabled] / Auto
FullSpeed / [HiSpeed]
Disabled / Enabled / [Auto]
[Auto] / Floppy / Forced FDD / Hard
Disk / CDROM
Option
Disabled / [Enabled]
[60% Duty Cycle] / 45% Duty Cycle
/ 30% Duty Cycle
Read Only
Description
Enable or disable the integrated SATA
controller.
To select the hard disk drive mode.
If this option is set to IDE, all the
SATA connectors will be configured
as stand-alone SATA connectors.
Description
Select the I/O base address and
interrupt for serial port 1.
Select the I/O base address and
interrupt for serial port 2.
Description
Enable or disable the support on
legacy USB devices.
Select the USB speed.
Enable or disable the support on the
hot-swap USB diskette drive.
Select the type of the USB device.
Description
If this option is set to Disabled, the
fan runs at the full speed; if this option
is set to Enabled, the fan speed is
controlled by the system temperature.
Select the PWM Minimal Duty Cycle
for the fan: 60%-100%, 45%-100%,
or 30%-100%.
The sensor data in this option is for
read only. The detected data includes
the temperature, voltage and fan
speed.
.
Chapter 6
Configuring the server
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkserver 4010Thinkserver 1044Thinkserver 4011

Table of Contents