1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See "Removing the server cover" on page 19.
3. Locate the memory slot with the memory module that you want to remove. See "Locating parts on the
system board" on page 13 for the locations of the memory slots.
4. Carefully open the retaining clips on each end of the memory slot and then grasp the memory module
straight up by its edges.
Figure 11. Removing the memory module
5. If you are instructed to return the failing memory module, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the removal procedure, go to "Completing the parts replacement" on page 64.

Removing or installing internal drives

This section provides instructions on how to remove or install internal drives for the server.
See "Specifications" on page 5 for information about the types of internal drives that the server supports and
other important information, and see "Front view" on page 9 for the locations of the drive bays in the server.
When installing an internal drive, be sure to consider the following information:
• Make sure that you have all the cables and other equipment that is specified in the documentation that
comes with the drive.
• Select the drive bay in which you want to install the drive.
• Check the instructions that come with the drive to see whether you have to set any switches or jumpers
on the drive. If you are installing a SAS device, be sure to set the SAS ID for that device.
• The EMI integrity and cooling of the server are protected by having all bays, PCI slots, and PCI Express
slots covered or occupied. When you install a drive, PCI card, or PCI Express card, save the EMC
shield and filler panel from the bay, PCI card slot, or PCI Express card slot in the event that you later
remove the device.
• For a list of the supported hard disk drives for your server, go to http://www.lenovo.com/thinkserver. On
the ThinkServer systems page, click Products ➙ Options ➙ ThinkServer Hard Drives.
.