Problem
A. Pilot is not lit.
B. Loose, dirty, or corroded terminals
C. Loose, dirty, or corroded terminals
D. Thermostat, gas valve, or hi-limit
Burner does
not light at all.
E. Thermostat out of calibration.
F. If the above causes have all been
A. One or more burner orifices
B. Blocked flue.
C. Fryer flue connected directly to
Burner does
not light all the
way around.
D. If the above causes have all been
Probable Cause
on gas valve.
on thermostat.
wires broken or shorted.
ruled out, the probable causes are
a failed thermostat or a failed gas
valve.
clogged.
vent hood with a chimney-like
duct.
ruled out, the probable causes are
a broken or missing target (GF40),
a bent or missing flame deflector
(GF14), or incorrect burner gas
pressure.
Corrective Action
A. Light pilot.
B. Clean and tighten terminals on gas
valve.
C. Clean and tighten terminals on
thermostat.
D. Examine wires for signs of
abrasions, cuts, kinks, etc. If the
wiring is obviously damaged, it
will probably be necessary to
replace the associated component.
Call FASC.
E. Check calibration of thermostat in
accordance with procedures in
Section 4.2 of this manual.
F. Call FASC.
A. Turn gas valve knob to OFF
position. Use thin wire to clear
obstruction from burner orifices.
B. Clear blockage from flue.
C. Remove chimney-like duct and
allow for at least 18" (45.7cm) be-
tween flue outlet and vent hood
filters.
D. Call FASC.
4-5