Remote Maintenance
Event Trace Buffer
The Event Trace Buffer is used to store and dump event traces (up to 30) that occur just prior
to a
STARPLUS
personnel to aid in system troubleshooting.
The basic format for the commands are as follows:
Command
t<space><return>
t<space>0<return>
t<space>1<return>
t<space>2<return>
t<space>3<return>
d<space>e <return>
d<space>b <return>
r<space> sXXX<return>
r<space> cXXX<return>
Press the Esc key to abort the Data Dump and return to the maint> prompt.
Triad-S™
System soft or hard restart. These can then be reviewed by authorized
Table 4-7: Event Trace Buffer Commands
Displays the current status of the Event Trace Buffer.
Turns the Trace buffer OFF.
Turns the Trace buffer ON to record events prior to a soft
system reset.
Turns the Trace buffer ON to record events prior to a hard
system restart.
Turns the Trace buffer ON to record events prior to either a soft
reset or a hard system restart.
Dumps Trace Events stored from last system reset (soft or hard).
Permits maintenance personnel to determine the busy status
of all the busy keysets and CO Lines in the system, including the
T1 lines.
Permits a specific station to be reset.
Permits a specific CO Line to be reset.
Chapter 4 - Maintenance and Troubleshooting
Function
4-13