Parts Replacement - U-Line 2115R Service Manual

Échelon models origins models
Hide thumbs Also See for 2115R:
Table of Contents

Advertisement

Parts Replacement

NOTE: Echelon models do not require removal of the ice maker or freezer
housing to access the fan motor, drain or evaporator.
REPLACING EVAPORATOR FAN MOTOR
- CO2175F/2175RF
1. Disconnect unit from power source.
2. Remove two screws (Figure 58) from fan cover.
3. Remove two screws holding fan bracket to liner.
4. Unplug fan connection.
5. Remove two nuts holding the fan to the fan bracket.
6. Replace with new fan.
Evaporator cover
Fan cover
screws
Evaporator cover
screws
screws
Figure 58. CO2175F/2175RF
Section 3 - Service and Repair
7. Plug in the fan connection.
8. Reinstall fan bracket to liner, making sure the fan wires are tucked
behind the fan bracket.
9. Reinstall unit and test.
ACCESSING EVAPORATOR OR DRAIN
- CO2175F/2175RF
1. Disconnect unit from power source.
2. Remove two screws (Figure 58) from fan cover.
3. Remove three screws from evaporator cover.
4. To remove, pull evaporator cover forward and turn.
Fan bracket screw
Nuts
Fan bracket screw
ULIN_0371_A
3-55