Refrigeration System Diagnosis Guide; Defrost Information - All Models - U-Line 2115R Service Manual

Échelon models origins models
Hide thumbs Also See for 2115R:
Table of Contents

Advertisement

Refrigeration System Diagnosis Guide

System
Suction
Condition
Pressure
Normal
Normal
Overcharge
Higher than
normal
Undercharge
Lower than
normal
Partial
Somewhat
Restriction
lower than
normal -
in vacuum
Complete
In deep
Restriction
vacuum
No Gas
0 PSIG
to 25"

DEFROST INFORMATION - ALL MODELS

Model
2175R
2115R
2175WC
2115WC
2175BEV
2175/2275DWRR
CO2175F
2175RF
CO21752275DWR
CLRCO2175
2275DWRWS
2275ZWCS/2275ZWCOL
1115R
1175R/ADA24R
1115WC
1175WC
1175BEV
Suction
Compressor
Line
Discharge
Slightly below
Very hot
room
temperature
Very cold -
Slightly warm
may frost
to hot
heavily
Warm -
Hot
near room
temperature
Warm -
Very hot
near room
temperature
Room
Room
temperature
temperature
(cool)
(cool)
Room
Cool to hot
temperature
(cool)
Hours Between Defrost Time
(Runtime) (Adjustable)
6
6
6
6
6
6
12
12
12
6
12
12
4
6
6
6
6
Section 3 - Service and Repair
Condenser
Capillary
Tube
Very hot
Warm
Hot to warm
Cool
Warm
Warm
Top passes
Room
warm -
temperature
lower passes
(cool) or colder
cool (near room
temperature
due to liquid
Room
Room
temperature
temperature
(cool)
(cool)
Room
Room
temperature
temperature
(cool)
(cool)
Length/min
90
90
90
90
90
90
18*/45
18*/45
18*/45
90
90
75
60
45
45
45
45
Evaporator
Wattage
Cold
Normal
Cold
Higher than
normal
Extremely cold
Lower than
near inlet -
normal
outlet below
room
temperature
Extremely cold
Lower than
near inlet -
normal
outlet below
room
temperature
backing up
No
Lower than
refrigeration
normal
No
Lower than
refrigeration
normal
Stop Point
42°
42°
45°
45°
42°
42°
42°
42°
42°
42°
45° (both drawers)
45° (both zones)
-
-
-
-
-
3-41