7. SUPPORTING STRUCTURE ASSEMBLING MANUAL
7.2.
Parallel to pitched roof
Installation sequence
The roof brackets supplied are suitable for use with a wide range of roof
tiles. The brackets must be fixed to the roof rafter with appropriate fixings
suitable for the rafter material. If the rafter is wood then it is advisable to
pre drill the holes for the fixings to ensure the timber does not split. Ensu-
re the drill used is smaller than the fixing to allow correct tightening of the
fixing can be made.
(Figure 43, Figure 44 and Figure 45)
Appropriate roofing material
(eg Lead/ Felt )
1
2
4
3
Figure 43. Anchors for flat tiles.
Figure 44. Anchor for mechanical tiles (ava-
ilable as an accessory kit)
Figure 45. Anchor fixed on a pitched roof.
26
Solargen solar PV