Command "i": save user settings
Description: Via this command the
user settings. These are the features to be saved:
connection of
connection of
status of
auto switch
The
RCS
register about status of auto switch, outputs and inputs.
The configuration is saved on the device itself.
Example:
The command
<STX> <TYPE> <ADDRH> <ADDRL>
Message
Let's assume that there is a sync signal on
, and both outputs are connected to
INPUT 2
Status
Auto Switch
1
Acknowledge <STX> <TYPE> <ADDRH> <ADDRL>
Result:
The current configuration is saved as user settings.
Command "q": read user settings
Description: Via this command the
figuration. These are the desired information:
(target) connection of
(target) connection of
status of
auto switch
Depending on autoswitch enabled or disabled and depending on the presence of a sync
signal on the inputs in question, the true connections might differ from the target connec-
tion. That's why the user might want to read the target configuration of the saved user set-
tings.
The
RCS
register about status of auto switch, outputs and inputs.
Example:
The command
Message
<STX> <TYPE> <ADDRH> <ADDRL>
tells the
RCM
DIGITAL OUTPUT 1
DIGITAL OUTPUT 2
executes the command and sends the acknowledge which informs via the status
is sent to the second
i
m
0
2
Out2
Out1
true
true
0
0
m
0
2
tells the
RCM
DIGITAL OUTPUT 1
DIGITAL OUTPUT 2
executes the command and sends the acknowledge which informs via the status
is sent to the second
q
m
0
2
of class m to save the current configuration as
RCS
:
RCS
<Body>
<STATH> <STATL <CHKH> <CHKL> <ETX>
i
, no sync signal on
DIGITAL INPUT 1
DIGITAL INPUT 1
Reserved Out2
Out1
target
target
0
0
<Body>
<STATH> <STATL <CHKH> <CHKL> <ETX>
i
8
of class m to read the currently saved user con-
RCS
:
RCS
<Body>
<STATH> <STATL <CHKH> <CHKL> <ETX>
q
3
8
DIGITAL
, a
is enabled:
uto switch
Prsnt2 Prsnt1
0
0
1
1
a
1
4
0

Advertisement