INSTALLATION
CONDITION
____________________________________________
10. The flowmeter cavity is filled _____
with lube oil (10W30) to a
level 3/8 inch from the bottom.
Replenish if necessary.
DO NOT OVERFILL.
11. The intensifier fluid reservoir _____
is filled with oil. If additional
oil is required, add SAE 10-
W30 motor oil.
____________________________________________
Do not proceed until all responses on the
checklist are "YES".

2.7 Start-up

1. Switch the On/Off Switch on the left side of the
calibrator to ON.
The POWER indicator, the HEATER indicator and
the red dot on the display will be lit, and the
circulating and clamp cylinder pump will be
running.
2. Allow the calibrator to warm up until the CAL
FLUID TEMPERATURE gauge indicates 104°F
±1°F (40°C). This usually takes about 15 to 20
minutes, depending on the ambient tempera-
ture.
The HEATER indicator light will be lit while the
heater is on. When the fluid reaches the proper
temperature, the light will go out.
3. The calibrator is now ready for testing injectors.
Follow procedures in Section 3.0 for Cummins and
DD injectors.
Page 2-6
YES
NO
_____
_____
Figure 2-15 Initial Checks - Flowmeter Cavity
Bacharach, Inc.
INJECTOR CALIBRATOR CD3
11 Intensifier Reservoir
Figure 2-16. Initial Checks - Intensifier
2 Wait Till Temperature Reaches 104°F
1 Lit During Warm-up
Figure 2-17. Start-up
Instructions 67-9319