Preface; Features; Specifications - Friedrich KP05A10 KP06A10 Service And Parts Manual

Kp line 115volts
Table of Contents

Advertisement

1. PREFACE

This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 FEATURES

• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE

1.2 SPECIFICATIONS

MODELS
ITEMS
COOLING CAPACITY (BTU/h)
POWER SUPPLY (Phase, V, Hz)
INPUT (W)
OPERATING CURRENT (AMP.)
REFRIGERANT CONTROL
REFRIGERANT CHARGE (R-22)
INSIDE FAN
OUTSIDE FAN
AIR DISCHARGE
CHASSIS
PROTECTOR
TEMPERATURE CONTROL
FAN MOTOR
KP05A10
5,100
1ø, 115V, 60HZ
470
4.4
CAPILLARY TUBE
330g (11.6 oz)
TURBO FAN
PROPELLER FAN WITH SLINGER RING
2-WAY (RIGHT AND LEFT)
TOP-DOWN
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
THERMISTOR
6 POLES, 21W
—3—
KP06A10
5,700
530
4.8
365g (12.9 oz)
6 POLES, 27W

Hide quick links: